Hanna Instruments (M) Sdn Bhd
11A, Jalan PJS 11/20,
Bandar Sunway,
46150 Petaling Jaya,
Selangor, Malaysia.
11A, Jalan PJS 11/20,
Bandar Sunway,
46150 Petaling Jaya,
Selangor, Malaysia.
+603-5638 9940
Penang Branch Office
Hanna Instruments (M) Sdn Bhd
N0. 303-2-27, Krystal Point,
Jalan Sultan Azlan Shah,
11900 Sungai Nibong,
Penang, Malaysia.
+604-638 4558
+604-645 4558
penang@hannamalaysia.com
Sabah Branch Office
Hanna Instruments (M) Sdn Bhd
No. 4-1, 1st Floor,
Plaza Kingfisher,
Jalan Plaza Kingfisher 5,
Inanam, 88450 Kota Kinabalu,
Sabah, East Malaysia.
088-382 941
088-382 942
sabah@hannamalaysia.com
Hanna Instruments (M) Sdn Bhd
N0. 303-2-27, Krystal Point,
Jalan Sultan Azlan Shah,
11900 Sungai Nibong,
Penang, Malaysia.
+604-638 4558
+604-645 4558
penang@hannamalaysia.com
Sabah Branch Office
Hanna Instruments (M) Sdn Bhd
No. 4-1, 1st Floor,
Plaza Kingfisher,
Jalan Plaza Kingfisher 5,
Inanam, 88450 Kota Kinabalu,
Sabah, East Malaysia.
088-382 941
088-382 942
sabah@hannamalaysia.com
HI8410 Dissolved Oxygen Controller with Extended Range and Analog Output
Previous | 17 / 31 | Next |
RM 4,130.00
1.8 kg
The HI8410 is a panel mounted dissolved oxygen controller that is used to maintain and monitor the concentration of DO in a wide range of industrial process applications. The HI8410 uses a Galvanic probe that typically requires less maintenance than a Polarographic style making it ideal for long term monitoring.
- Fail Safe Alarm System protects these meters against the pitfalls of process control.
- Low maintenance Galvanic probe.
Fail Safe Alarm Syste
- Hanna’s exclusive Fail Safe Alarm System protects against problems caused by power supply failure or signal interruption, which are typical risks in industrial environments. An alarm condition is indicated by a red LED, located directly on the front panel of the controller.
Simple to Use
- The instruments are designed with a standard DIN panel mount with membrane keypads and large LCD with backlight on the front, and provide a series of auto-diagnostic functions.
Automatic Temperature Compensation
- The Dissolved Oxygen readings are automatically compensated for the temperature effects on the oxygen solubility and membrane permeability. M
Analog Output
- To enhance troubleshooting and the ability to record data while monitoring, simply attach a recording device to the instrument’s 4 to 20 mA output contacts, conveniently located on the front panel, to obtain a copy of the results on demand.
Salinty Compensation
- The salinity compensation feature allows the determination of Dissolved Oxygen even in salty waters.
Diagnostic Tests
- The HI 8410 controllers are designed with built-in diagnostic functions to enable the user to check and troubleshoot the instrument. The checks performed are through the front panel keys and can be used to isolate the cause of malfunction.
Oxygen, Dissolved
Oxygen, Dissolved Measurement Type | galvanic: HI76410/4 with 4 m (13.1’) cable or HI76410/10 with 10 m (32.8’) cable (not included) |
---|---|
Oxygen, Dissolved Range | 0.0 to 50.0 mg/L (ppm) O₂; 0 to 600 % O |
Oxygen, Dissolved Resolution | 0.1 mg/L (ppm) or 1% (O₂) |
Oxygen, Dissolved Accuracy | ±1% of reading (O₂) |
Oxygen, Dissolved Calibration | manual, one point, in saturated air |
Oxygen, Dissolved Temperature Compensation | automatic, from -5 to 50°C (23 to 122 °F) |
Salintiy Compensation | 0 to 51 g/L (resolution 1 g/L) |
Oxygen, Dissolved Dosing Relay | 1, isolated, 2A, max. 240V, resistive load, 1,000,000 strokes |
Oxygen, Dissolved Dosing Set Point | 1 to 600 % O2; 0.1to 50.0 mg/L (mg/L (ppm) O₂ |
Oxygen, Dissolved Hysteresis Band | 0.5 to 2.4 mg/L (ppm) O₂ |
Process Control Meter
Alarm Relay Range | 1.0 to 5.0 mg/L (ppm) O₂ |
---|---|
Dosing Control | OFF/AUTO/ON with selection switch |
Over Dosing Control | adjustable, from 5 min to 60 min with knob or disable by wire strap - on rear panel |
Backlight | continuous on |
Enclosure | flame retardant ABS body and front panel; transparent splash-proof front cover |
Panel Cutout | 141 x 69 mm (5.6 x 2.7’’) |
Recorder Output | 0 to 20 mA or 4 to 20 mA (isolated) |
Power Supply | 230 VAC ±10%; 50/60 Hz |
Environment | 10 to 50°C (14 to 122°F); RH max 95% non-conndensing |
Weight | 1 kg (2.2 lb.) |
Ordering Information | The HI8410 is supplied with mounting brackets and instructions. Probes (not included): HI76410/4: Galvanic DO probe (fixed) with internal temperature sensor, DIN connector and 4 m (13.1’) cable HI76410/10: Galvanic DO probe (fixed) with internal temperature sensor, DIN connector and 10 m (32.8’) cable |