Hanna Instruments (M) Sdn Bhd
11A, Jalan PJS 11/20,
Bandar Sunway,
46150 Petaling Jaya,
Selangor, Malaysia.
+603-5638 9940
Penang Branch Office
Hanna Instruments (M) Sdn Bhd
N0. 303-2-27, Krystal Point,
Jalan Sultan Azlan Shah,
11900 Sungai Nibong,
Penang, Malaysia.
+604-638 4558
+604-645 4558
penang@hannamalaysia.com

Sabah Branch Office
Hanna Instruments (M) Sdn Bhd

No. 4-1, 1st Floor,
Plaza Kingfisher,
Jalan Plaza Kingfisher 5,
Inanam, 88450 Kota Kinabalu,
Sabah, East Malaysia.
088-382 941
088-382 942
sabah@hannamalaysia.com


*HI3820-100 Acidity Chemical Test Kit Replacement Reagents (100 tests)

Previous 28 / 33 Next

*HI3820-100 Acidity Chemical Test Kit Replacement Reagents (100 tests) Chemical Test Kit Reagents Reagents
RM 251.00
300 g
In Stock


Download Files

us_hi3820_0_ghs_usa_1.pdf (279.87 KB)
The HI3820-100 are reagents for the determination of acidity by titration with the acidity chemical test kit. There are enough reagents for approximately 100 tests to be used with Hanna’s test kit. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.

  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability

Details

The HI3820-100 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate acidity measurements with the chemical test kit. These reagents follow the methyl orange/phenolphthalein method to determine strong acid/total acid concentration.

For strong acid determination, also known as methyl orange acidity, the sodium hydroxide titrant reacts with acids present in the sample. With addition of bromophenol blue indicator, the solution turns from yellow to green/blue as it reaches the pH endpoint near pH 4.5. For total acid determination, also known as phenolphthalein acidity, sodium hydroxide is also used as the titrant. With addition of phenolphthalein indicator, the solution turns pink as it reaches the pH endpoint near pH 8.3. The number of milliliters of titrant used to reach the appropriate endpoint will determine the acidity as mg/L CaCO3. These reagents are designed to be used with samples that have an expected acidity range of 0 to 100 mg/L and 0 to 500 mg/L CaCO3.

 

Specifications


 
Package bottles
Quantity 100 tests
Method methyl orange / phenolphthalein

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Subscribe Newsletter