Hanna Instruments (M) Sdn Bhd
11A, Jalan PJS 11/20,
Bandar Sunway,
46150 Petaling Jaya,
Selangor, Malaysia.
+603-5638 9940
Penang Branch Office
Hanna Instruments (M) Sdn Bhd
N0. 303-2-27, Krystal Point,
Jalan Sultan Azlan Shah,
11900 Sungai Nibong,
Penang, Malaysia.
+604-638 4558
+604-645 4558
penang@hannamalaysia.com

Sabah Branch Office
Hanna Instruments (M) Sdn Bhd

No. 4-1, 1st Floor,
Plaza Kingfisher,
Jalan Plaza Kingfisher 5,
Inanam, 88450 Kota Kinabalu,
Sabah, East Malaysia.
088-382 941
088-382 942
sabah@hannamalaysia.com


HI7091L Pretreatment Reducing Solution for ORP electrodes (500 mL)

Previous 11 / 13 Next

HI7091L Pretreatment Reducing Solution for ORP electrodes (500 mL) Cleaning Solutions Solutions
RM 139.00
1 kg
In Stock


Download Files

us_hi7091_2_before_mixing_ghs_usa_1.pdf (328.22 KB)
HI7091L is a reducing pretreatment solution for the conditioning an ORP electrode that is used to measure reduction reactions. Hanna pretreatment solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.

  • Prepared with reagent grade chemicals
  • Conditions ORP electrodes for fast response
  • Air-tight seal to ensure the quality of the solution

Details

ORP (Oxidation Reduction Potential) electrodes are used to measure a chemical reaction in which one species is being oxidized and another is being reduced. The loss of electrons by an element or compound is known as oxidation reaction while the gaining of electrons by an element or compound is known as reduction reaction. For example, plating companies that have hexavalent chromium (Cr6+) in their wastewater must reduce it to a safer trivalent chromium (Cr3+) form. This reduction reaction occurs in the presence of a strong reductant such as sodium metabisulfite. The addition of the reductant must be measured with an ORP electrode to ensure that there is an adequate reducing potential. Using the HI7091L reducing pretreatment solution prior to taking a measurement provides for a faster response time in a reducing environment.

To use, soak the ORP electrode in the pretreatment solution for 15 minutes prior to use. As a general rule, if the mV reading corresponding to the pH measurement is lower than the value in the table below the reducing pretreatment solution (HI7091) is used. If the mV reading corresponding to the pH measurement is higher than the value in the table below then the oxidizing pretreatment (HI7092) should be used.
 

pH Value

mV Value

pH Value

mV Value

pH Value

mV Value

pH Value

mV Value

pH Value

mV Value

0

990

3

800

6

640

9

460

12

280

1

920

4

740

7

580

10

400

13

220

2

860

5

680

8

520

11

340

14

160


The HI7091 bottle is labeled with

  • Product code

  • Lot number

  • Expiration date

Air tight bottle with tamper-proof seal

  • Ensures quality and freshness of solution


Specifications

Description reducing pretreatment solution
Package bottles
Size 500 mL
Quantity 1
Certificate of Analysis No








 

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version