HI98161 Professional Foodcare Portable pH Meter

Previous 21 / 21 Next

HI98161 Professional Foodcare Portable pH Meter pH Portable Meters HI98161 Professional Foodcare Portable pH Meter pH Portable Meters
RM 3,938.00
1 kg
In Stock


Download Files

man98161_07_16_single.pdf (0.97 MB)
Waterproof-Food-Meters-Hanna

The HI98161 is a rugged, waterproof, portable pH meter that measures pH and temperature using the specialized FC2023 Foodcare pH electrode. This professional, waterproof meter complies with IP67 standards. The HI98161 is supplied with all necessary accessories to perform a pH/temperature measurement packaged into a durable thermoformed carrying case that holds the meters, probes and calibration buffers securely in place.


  • Quick Connect DIn Connector
  • USB Connection for Data Transfer
  • Dedicated Help Button

Details

One of the most common measurements of food products is pH. The pH influences many qualities of food products including flavor, fermentations, texture, appearance and shelf stability. Foods are generally broken into two groups based on their pH value. These groups include acid foods which have a naturally low pH of 4.6 or below and low-acid foods that have a finished equilibrium pH values greater than pH 4.6 and a water activity greater than 0.85. The low-acid foods can be pH adjusted with an acid to lower the final pH and become an acidified food. Maintaining a lower pH will help in preventing unwanted bacteria from growing.

Food products can provide a number of challenges for the person that needs to measure pH. Food products tend to be solid, semi-solid or as a slurry with a high content of solids. All three types of samples will coat the sensitive glass membrane surface and/or clog the reference junction. The FC2023 that is supplied with the HI98161 is designed specifically for measuring pH in food. From a conic tip shape for easy penetration, open junction that resist clogging, and a Polyvinylidene fluoride (PVDF) food grade plastic body that is resistant to most chemicals and solvents, including sodium hypochlorite. It has high abrasion resistance, mechanical strength and resistance to ultraviolet and nuclear radiation. PVDF is also resistant to fungal growth. The FC2023 is an ideal general-purpose pH electrode for food products that connects to the HI98161 with a quick-connect, waterproof DIN connector, allowing for a secure, non-threaded attachment.

The FC2023 is the ideal electrode to measure the pH of milk, yogurt, meats, cheeses, fruit, sushi, rice, jams, jellies, dough, ice cream, yogurt, beverages, and juice.




conical glass tip

Conical Glass Tip

The conical shaped tip design allows for penetration into solids, semi-solids, and emulsions for the direct measurement of pH in food products including meat, cheese, yogurt, and milk. 



open junction reference

Open Junction Reference

The open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it impermeable to clogging, resulting in a fast response and stable reading.


 

pvdf body


PVDF Body

Polyvinylidene fluoride (PVDF) is a food grade plastic that is resistant to most chemicals and solvents, including sodium hypochlorite. It has high abrasion resistance, mechanical strength and resistance to ultraviolet and nuclear radiation. PVDF is also resistant to fungal growth.

 

Besides being supplied with a unique foodcare pH electrode, the HI98161 has the Hanna's unique CAL Check™ feature that alerts the user to potential problems during the calibration process. This is a very important for the food processor since it is likely that the probe will be coated with the solids found in the food product being measured. This coating can easily lead to errors in pH measurement. By comparing previous calibration data to the current calibration, the meter will inform the user, with display prompts, when the probe needs to be cleaned, replaced, or if the pH buffer might be contaminated. After calibration, the overall probe condition is displayed on screen as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode, both of which can be found in the GLP data.

Pressing the “AutoHold” virtual key in measurement mode, the meter will freeze and automatically log a stable reading. An “out of calibration range” warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.

The log-on-demand mode allows the user to record and save up to 200 samples. The logged data, along with the associated GLP data, can then be recalled or transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software for traceability in record keeping for specific product batches. GLP data includes date, time, calibration buffers, offset, and slope, and is directly accessible by pressing the dedicated GLP key.

A contextual help menu based on the screen that is currently being viewed can be accessed at any time by the press of a dedicated button.

The high contrast, graphic LCD screen is easy to view outdoors in bright sunlight as well as in low-lit areas with the backlight. A combination of dedicated and virtual keys allows for easy, intuitive meter operation in a choice of languages.

The compact, durable HI720161 carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter and electrode, beakers, buffer solutions and cleaning solutions.


 

On-Screen Features

 


Setup screen
Our extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides.




Calibration
pH calibration features detailed CAL Check™ messages. Users are guided through the calibration procedure with step-by-step on-screen instructions.



GLP
GLP
Comprehensive GLP functions are directly accessible by pressing the GLP key. Calibration data, including: date, time, offset, slope and buffers used in the last calibration can be reviewed.

Features/Benefits:

Ergonomic, rugged, waterproof (IP67) design

Supplied with FC2023 Foodcare pH/Temperature electrode

  • Body made of food grade PVDF plastic
  • Conic tip shape for easy penetration into semi-solids
  • Open junction design that resist clogging from food solids
  • Low temperature pH sensing glass suitable for refrigerated products
  • Built in temperature sensor for temperature compensated measurements

Five-point pH calibration with seven standard buffers and five custom buffers

CAL Check

  • Alerts user to potential problems during calibration including when to clean electrode and possible buffer contamination
  • Displays overall condition of the pH electrode after calibration that is based on the offset and slope characteristics

Log-on-demand

  • Store measurement data at the press of a button

AutoHold

  • Freezes displayed measurement reading upon stabilization

GLP Features

  • GLP data including date, time, pH calibration buffers, offset, and slope
  • GLP data stored with logged data for traceability

Calibration timeout to alert the user at a defined interval when the calibration has expired

Multiple language selection

200 hour battery life with battery level displayed on measurement screen

Menu driven for ease of use with virtual-key extended functionality

Contextual help at the press of a button

Backlit, graphic LCD

Connectivity

  • PC connectivity via a sealed opto-isolated micro USB and HI92000 software

Specifications

pH Range -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH
pH Resolution 0.1 pH; 0.01 pH; 0.001 pH
pH Accuracy ±0.1; ±0.002 pH
pH Calibration up to five point calibration, seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + five custom buffers
mV Range ±2000 mV
mV Resolution 0.1 mV
mV Accuracy ±0.2 mV
Temperature Range -20.0 to 120.0°C (-4.0 to 248.0°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±0.4°C (±0.8°F) (excluding probe error)
Temperature Compensation manual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)
Slope Calibration from 80 to 110%
Electrode/Probe FC2023 Foodcare PVDF body, pH electrode with internal temperature sensor, quick connect DIN connector and 1 m (3.3’ cable)
Input Impedance 10¹² Ohms
Log-on-demand 200 samples (100 pH and 100 mV range)
PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable
Battery Type/Life 1.5V AA batteries (4) / approximately 200 hours of continuous use without backlight (50 hours with backlight)
Auto-off user selectable: 5, 10, 30, 60 min or can be disabled
Environment 0 to 50°C (32 to 122°F); RH 100% (IP67)
Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight 400 g (14.2 oz.)
Ordering Information HI98161 is supplied with FC2023 PVDF body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI700641 electrode cleaning solution for dairy products sachet (2), 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual with quick start guide, instrument quality certificate and HI720161 hard carrying case.


 

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Recent Updates