Hanna Instruments (M) Sdn Bhd
11A, Jalan PJS 11/20,
Bandar Sunway,
46150 Petaling Jaya,
Selangor, Malaysia.
+603-5638 9940
Penang Branch Office
Hanna Instruments (M) Sdn Bhd
N0. 303-2-27, Krystal Point,
Jalan Sultan Azlan Shah,
11900 Sungai Nibong,
Penang, Malaysia.
+604-638 4558
+604-645 4558
penang@hannamalaysia.com

Sabah Branch Office
Hanna Instruments (M) Sdn Bhd

No. 4-1, 1st Floor,
Plaza Kingfisher,
Jalan Plaza Kingfisher 5,
Inanam, 88450 Kota Kinabalu,
Sabah, East Malaysia.
088-382 941
088-382 942
sabah@hannamalaysia.com


HI84533-50 Titrant for Formol Number Mini Titrator

Previous 4 / 6 Next

HI84533-50 Titrant for Formol Number Mini Titrator Titration Reagents Reagents
RM 165.00
500 g
In Stock


The HI84533-50 is a 230 mL bottle of titrant solution for use with the HI84533 Formol Number Mini Titrator for Wine and Fruit Juice Analysis.

 

The HI84533-50 titrant solution is used for both the low and high ranges of formol number. The titrant is pre-standardized, eliminating the need for any volumetric glassware or a analytical balance and ensuring titrations are fast, accurate, and simple to perform.

  • Pre-standardized titrant
  • Clearly marked expiration date and lot number
  • Air tight bottle with tamper-proof seal

Details

The HI84533-50 is a 230 mL bottle of alkaline titrant solution that is used for both low and high range determinations of formol number in wine. The HI84533 mini titrator is designed to determine the formol number of wine and fruit juice by potentiometric titration in both a low range (30.0 to 400.0 mg/L as N) and high range (300 to 1000 mg/L as N).

The content of amino acids and other nitrogen compounds in wine or fruit juice is determined by an acid base titration to a fixed pH endpoint and expressed as total assimilable nitrogen. The determination of formol number is possible only after neutralization of the titratable acids present by a pH adjustment with HI84533-62 reagent, followed by the blockage of the amino groups by reaction with the HI84533-61 formol base reagent. The titration is then performed with the HI84533-50 titrant solution.

Replacement reagents required to operate the HI84533 include:

 

Low Range - 30.0 to 400.0 mg/L as N

High Range - 300 to 1000 mg/L as N

Pump calibration standard

HI84533-55

HI84533-55

Titrant solution

HI84533-50

HI84533-50

pH adjustment reagent

HI84533-62

HI84533-62

Formol base reagent

HI84533-61

HI84533-61

Additional reagent

HI84533-60

HI84533-60

 

Specifications

Package bottles
Size 230 mL
Quantity 1

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Subscribe Newsletter