*HI38022-100 Total Chlorine High Range Test Kit Replacement Reagents (100 tests)

Previous 16 / 86 Next

*HI38022-100 Total Chlorine High Range Test Kit Replacement Reagents (100 tests) Chemical Test Kits
RM 251.00
500 g
In Stock


The HI38022-100 are replacement reagents for the determination of total chlorine by titration with the HI38022 Total Chlorine High Range Test Kit. There are enough reagents for 100 tests to be used with Hanna’s test kit. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each bottle and packet for traceability.

  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability

Details

The HI38022-100 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate total chlorine measurements with the chemical test kit. These reagents follow an iodometric titration method to determine total chlorine concentration. This set includes 1 (30 mL) dropper bottle of potassium iodide solution, 100 packets sulfamic reagent, 1 (25 mL) dropper bottle of starch indicator, and 1 (100 mL) bottle thiosulfate reagent.

For determination of total chlorine, a reaction with iodide in acidic solution occurs with the chlorine present in the sample. The amount of iodine generated is equivalent to the chlorine in the sample. The liberated iodine is then titrated with standard sodium thiosulfate solution that reduces the iodine back to iodide ions. The number of drops of titrant used to reach the visual endpoint will determine the total chlorine concentration in mg/L. These reagents are designed to be used with samples that have an expected total chlorine range of 0.0 to 4.0 mg/L or 0.0 to 20.0 mg/L Cl2.
 

Specifications

Package bottles / packets
Method Iodometric
Number of Tests 100