Hanna Instruments (M) Sdn Bhd
11A, Jalan PJS 11/20,
Bandar Sunway,
46150 Petaling Jaya,
Selangor, Malaysia.
11A, Jalan PJS 11/20,
Bandar Sunway,
46150 Petaling Jaya,
Selangor, Malaysia.
+603-5638 9940
Penang Branch Office
Hanna Instruments (M) Sdn Bhd
N0. 303-2-27, Krystal Point,
Jalan Sultan Azlan Shah,
11900 Sungai Nibong,
Penang, Malaysia.
+604-638 4558
+604-645 4558
penang@hannamalaysia.com
Sabah Branch Office
Hanna Instruments (M) Sdn Bhd
No. 4-1, 1st Floor,
Plaza Kingfisher,
Jalan Plaza Kingfisher 5,
Inanam, 88450 Kota Kinabalu,
Sabah, East Malaysia.
088-382 941
088-382 942
sabah@hannamalaysia.com
Hanna Instruments (M) Sdn Bhd
N0. 303-2-27, Krystal Point,
Jalan Sultan Azlan Shah,
11900 Sungai Nibong,
Penang, Malaysia.
+604-638 4558
+604-645 4558
penang@hannamalaysia.com
Sabah Branch Office
Hanna Instruments (M) Sdn Bhd
No. 4-1, 1st Floor,
Plaza Kingfisher,
Jalan Plaza Kingfisher 5,
Inanam, 88450 Kota Kinabalu,
Sabah, East Malaysia.
088-382 941
088-382 942
sabah@hannamalaysia.com
HI8615 ORP Transmitter with 4-20 mA Galvanically Isolated Output
Previous | 21 / 31 | Next |
RM 3,133.00
1.5 kg
In Stock
The HI 8615 has been designed for transmitting ORP measurements from remote locations in industrial environments. It features two controls (one for 4 mA and one for 20 mA) to compensate for electronic drift and ambient temperature.
- Designed for transmitting ORP measurements from remote locations in industrial environments.
- Water resistant design for use in process control.
- Ideal for chromium hexavalent reductions, cyanide oxidation reactions and water sanitation.
Robust Design
- IP65 rating and a rugged polypropylene casing provide optimum protection even in harsh environments, making this instrument ideal for chromium hexavalent reductions, cyanide oxidation reactions and water sanitation.
BNC Connector
- The transmitters use a universal BNC socket for quick and secure connection to any electrode with a BNC connector.
Easy Calibration
- Calibration is performed by the adjustment of two independent trimmers — slope and offset.
Isolated Input
- The input is isolated from the current loop to eliminate problems related to ground loop, low insulation cables, multiple electrode connections, and a common mode voltage of up to 100V ensures true differential readings
Flexible for Your Needs
- The transmitter can be connected to any Hanna controller that accepts analog input.
Version with LCD
- HI8615 ”L” versions allow easy verification and monitoring of measured values and is easier to calibrate and maintain.
mV
mV Range | 0 to ±1000 mV; 4–20 mA |
---|---|
mV Resolution | (for “L” models) 1 mV; 0.01 mA |
mV Accuracy | ±5 mV; ±0.02 mA |
mV (ORP) Calibration | offset: ±0.8 mA/±100mV; slope: 90 to 110%; ±0.8 mA |
Process Control Meter
Recorder Output | 4-20 mA (isolated) |
---|---|
Load | max 500 Ohm |
Display | LCD only for HI8615LN |
Power Supply | HI8615N: 18-30 VDC; HI8615LN: 20-36 VDC |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
IP Rating | IP65 |
Dimensions | 165 x 110 x 71 mm (6.5 x 4.3 x 2.8’’) |
Weight | 1 kg (2.2 lb.) |
Ordering Information | HI8615N and HI8615LN (with display) is supplied with instructions. |