HI2030-02 edge® Multiparameter EC/TDS/Salinity Meter

Previous 2 / 6 Next

HI2030-02 edge® Multiparameter EC/TDS/Salinity Meter edge Tablet Meters HI2030-02 edge® Multiparameter EC/TDS/Salinity Meter edge Tablet Meters HI2030-02 edge® Multiparameter EC/TDS/Salinity Meter edge Tablet Meters HI2030-02 edge® Multiparameter EC/TDS/Salinity Meter edge Tablet Meters HI2030-02 edge® Multiparameter EC/TDS/Salinity Meter edge Tablet Meters HI2030-02 edge® Multiparameter EC/TDS/Salinity Meter edge Tablet Meters
RM 4,051.00
1 kg
In Stock


Download Files

edge_05_15.pdf (2.59 MB)
edge_brochure.pdf (1.56 MB)
edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with simplified menu and options while for those who require advanced features there is the full featured standard operating mode. The edge HI2030 EC/TDS/Salinity kit can can be upgraded at any time with additional probes to measure pH or Dissolved Oxygen.

  • edge features a 5.5” LCD display that you can clearly view from over 5 meters. The large display and it’s wide 150° viewing angle provide one of the easiest to read LCD’s in the industry.
  • edge features a capacitive touch keypad that gives a distinctive, modern look. Since the keypad is part of the screen, your buttons can never get clogged with sample residue.
  • edge features clear, full text guides displayed on the bottom of the screen. There is no need to decipher scrambled abbreviations or symbols; these helpful messages guide you through every process quickly and easily.

Details

edge® is packed with many cutting edge features to ensure accuracy and usability.


Digital Electrodes

Digital Electrodes

edge electrodes are highly advanced, featuring a built-in microchip that stores calibration information that is automatically retrieved by edge once the electrode is plugged in. These digital electrodes also feature an easy to plug in 3.5 mm connector so you never have to worry about the right angle or aligning pins.



Digital Electrodes

Four Ring Probe

The HI2030 edge EC/TDS/Salinity meter is supplied with the HI763100 four ring platinum conductivity probe that has a built in temperature sensor for automatic temperature compensated measurements. The four ring technology allows for a wide range of measurement with a single probe as compared to amperometric two pole probes that have a limited range and can suffer from polarization effects. The HI763100 probe has a glass and PVDF body with a PEI (polyetherimide ) sleeve. Both materials have excellent resistance against many aggressive chemicals.



3.5mm Probe Input
3.5 mm Probe Input

Plugging an electrode in has never been simpler, no alignments, no broken pins, just connect the 3.5 mm plug and get started.



edge® is incredibly versatile. It can be used in a variety of ways and in a variety of environments without taking up the space of a traditional benchtop meter.


wall mount

Wall Mount

Using the wall mount cradle (included), edge can be placed on a wall, leaving zero footprint on the benchtop space. The cradle has a built in connector to power edge and charge its batteries. edge's zero footprint is designed to save you valuable benchtop space.



Cradle

Cradle and Electrode Holder

edge is equipped with a benchtop cradle with an adjustable swivel electrode holder to charge and hold the edge securely in place at the optimium viewing angle.
 

edge® is incredibly thin and weighs only 8.8 oz., has an 8 hour battery life, and dual USB inputs.


usb
Two USB Ports

edge includes one standard USB for exporting data with a flash drive and a second micro USB port for you to connect to a computer for file export and for charging your edge when the cradle is not available.



data logging
Data Logging

edge allows you to store up to 1000 log records of data. Data can be logged on demand (200 records), on stability (200 records), or at a predefined interval (600 records). The information stored include current reading,date, time and GLP data.



basic mode
Basic Mode

edge offers both Basic and Standard Modes. In Basic Mode the edge as an EC meter reduces features to simplify operation. In Basic Mode the meter will only allow for automatic temperature compensation, auto ranging of readings, and automatic cell factor correction while calibrating. The temperature correction coefficient is fixed to 1.9% / oC and interval logging is not available. In Standard mode the user has options to change these features.


pH Specifications

pH Range -2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV
pH Resolution 0.001 pH, 0.01 pH, 0.1 mV
pH Accuracy (@25ºC/77ºF) ±0.2 mV, ±0.01 pH, ±0.002 pH
pH Calibration up to 5 points
pH Calibration Buffers 1.68, 10.01, 12.45, 4.01, 6.86, 7.01, 9.18, two custom buffers
pH Temperature Compensation ATC: -5.0 to 100.0ºC; 23.0 to 212.0°F*

EC Specifications

EC Range 0.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute EC)**
EC Resolution 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm
EC Accuracy (@25ºC/77ºF) ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater)
EC Calibration 1 point offset calibration (0.00 μS/cm in air), 1 point slope calibration in EC standard 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm

TDS Specifications

TDS Range 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (absolute TDS)**, with 0.80 conversion factor
TDS Resolution 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
TDS Accuracy (@25ºC/77ºF) ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
TDS Calibration through EC calibration
TDS Conversion Factor 0.40 to 0.80

Salinity Specifications

Salinity Range 0.0 to 400.0% NaCl, 0.01 to 42.00 PSU, 0.0 to 80.0 g/L*
Salinity Resolution 0.1% NaCl, 0.01 PSU, 0.01 g/L
Salinity Accuracy (@25ºC/77ºF) ±1% of reading
Salinity Calibration 1 point with HI 7037L 100% NaCl sea water standard (other scales through EC calibration)

DO Specifications

DO Range 0.00 to 45.00 ppm (mg/L), 0.0 up to 300.0% saturation
DO Resolution 0.01 ppm, 0.1% saturation
DO Accuracy ±1 digit, ±1.5% of reading
DO Calibration one or two points at 0% (HI 7040 solution) and 100% (in air)
DO Temperature Compensation ATC: 0 to 50 ºC; 32.0 to 122.0 °F
Salinity Compenstaion 0 to 40 g/L (with 1 g/L resolution)
DO Altitude Compensation -500 to 4000 m (with 100 m resolution)

Temperature Specifications

Temperature Range -20.0 to 120.0 ºC, -4.0 to 248.0 °F
Temperature Resolution 0.1 °C, 0.1 °F
Temperature Accuracy ±0.5 °C, ±1.0 °F

Additional Specifications

EC/TDS/Salinity Temperature Compensation Automatic -5 to 100º C (23 to 212º F) NoTC - can be selected to measure absolute conductivity.
Conductivity Temperature Coefficient 0.00 to 6.00% / ºC
pH Electrode Diagnostics Glass and reference junction diagnostics ( HI 11311 & HI 12301 only), out of calibration range , probe condition, response time
Logging up to 1000*** records organized in: Manual log-on-demand (Max. 200 logs), Manual log-on-stability (Max. 200 logs), Interval logging *** (Max. 600 samples; 100 lots)
Connectivity 1 micro USB port for charging and PC connectivity, 1 USB port for storage
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Battery Type/Life Built-in rechargeable battery with up to 8 hours of continuous use
Power Supply 5 VDC adapter (included)
Dimensions 202 x 140 x 12.7mm (8” x 5.5” x 0.5”)
Weight 250 g (8.82 oz)
Ordering Information HI2030-02(230V) EC kit includes: HI763100 Conductivity probe, 4 sachets of 1413 μS/cm conductivity standard, 2 sachets of 5000 μS/cm conductivity standard, 2 sachets of 12880 μS/cm conductivity standard, 2 sachets general purpose rinse solution, USB cable, benchtop docking station with electrode holder, wall mount cradle, 5 VDC power adapter, quality certificate and instruction manual.
Notes

* temperature limits will be reduced to actual probe/sensor limits 
** with temperature compensation function disabled
*** For standard mode only (logging)

 