HI763100 Digital EC/Temperature Electrode

Previous 1 / 3 Next

HI763100 Digital EC/Temperature Electrode EC/TDS Electrodes & Probes
RM 2,351.00
500 g
In Stock


The HI 763100 is a digital conductivity electrode with a built in temperature sensor. Compared to the amperometric design of other conductivity probes, the HI 763100 is potentiometric probe with platinum sensors which allows for the possibility to measure high or low conductivity ranges using one probe. This electrode features an integrated microchip which stores calibration data, electrode type, and serial number. This probe features a 3.5 mm connector designed exclusively to be used with Hanna Instruments edge® Tablet Meters.

  • Built-in Microchip
  • Internal Temperature Sensor
  • 3.5 mm Connector

Details


Built-in Microchip

The built-in microchip stores sensor type, serial number and calibration information including date, time, offset, slope, probe condition and buffers used. This information is automatically retrieved by edge® once the electrode is plugged in. The ability to transfer information allows for hot swapping of probes without having to recalibrate. All pH measurements are performed within the electrode and transferred digitally to the meter. This overcomes any noise issues associated with the traditional high impedance analog measuring system. Electrical noise can be generated from a built in temperature sensor and while working in a humid environment.

 

Potentiometric Measuring System

The four ring potentiometric measuring system allows measurement of a broad range of samples while minimizing the effects of polarization. The two outer rings apply and alternating voltage and induce a current loop in the solution, while the two inner rings measure the voltage drop induced by the current loops. This allows for a range of readings from very high to very low without changing electrodes.

Sleeve

The probe is surrounded by a chemically resistant plastic sleeve to maintain control external interferences from the sample. It also allows the current loop to be generated in a controlled area.


Internal Temperature Sensor

Since temperature is an important factor for measuring conductivity, a built in temperature sensor on the probe is very helpful. There is no need for an external temperature probe, so that measurements can be made easily. The coefficient used to correct for changes in temperature is β, which is expressed as a percentage of reading per degree of Celsius.

Features at-a-glance

  • Digital, microprocessor based - no high impedance signal to the meter
  • Potentiometric measuring system- suitable over a wide range of conductivities
  • Built-in temperature sensor - no need for an additional temperature probe
  • 3.5mm digital plug – easy to plug in, no alignment necessary
  • PEI body – highly durable and well-suited for field applications

Specifications
Body Material PEI
Type 4-ring
Insulator glass
Electrodes Platinum
Range 0 to 200 mS/cm
Body Length / Overall Length 120mm
Recommended Operating Temperature -5 to 100°C (23 to 212°F)
Temperature Sensor yes
Amplifier no
Other Unique serial ID
Digital yes
Compatible Meters edge multiparameter
Cable 1 m (3.3')

 
Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Subscribe Newsletter