HI 510 Process Controller Universal

Previous 1 / 31 Next

HI 510 Process Controller Universal Controllers, Analyzers & Transmitters Process Controllers
RM 5,835.00
1.6 kg
In Stock


HI510 is designed to adapt to a user’s unique process control requirements. The controller has a large backlit dot matrix display for easy viewing and provides for an intuitive interface for setup options. The controller utilizes multi-color LEDs for easy viewing of the instruments’ status including relay activation, in alarm mode, or in hold status. All programming operations are done through the low profile vulcanized rubber keypad or using the RS485 connection to a PC operating the HI92500 Windows® compatible software.

 

  • Digital input for pH and ORP probes
  • Up to 5 relays for control and cleaning sequence
  • Up to 4 analog output for control and monitoring

HI510 is an advanced universal process controller that can be configured for many applications requiring monitoring and/or control of process parameters. It features a digital probe input that will automatically detect and update the controller with the parameter that it measures.

This controller can be configured with up to 5 control relays and 4 analog outputs. The control relays can be programmed for on/off, Proportional, or PID (Proportional Integral Derivative) types of control or used for programming cleaning sequences triggered by a digital input or based on a schedule. The scalable analog outputs can be used for remote devices including Chart recorders, PLC, or SCADA. The analog outputs can be used for control devices including dosing pumps and valves that accept a 0/4-20 mA output.

HI510 features a RS485 digital output that allows up to 32 devices to be connected to a single line that can be viewed and programmed remotely using the HI92500 software. The HI92500software provides for graphic user interface that allows for settings to be changed and saved for transfer to another HI510 controller.

The HI510 NEMA 4X enclosure uses sealed cable glands to maintain waterproof integrity. The versatile mounting kits allow for mounting the HI510 to a wall, pipe and panel.
 

More Information

More Information
SKU HI510
Product Name Universal Process Controller - HI510
Quote Required No
Dosing Control on/off, proportional and PID
Dosing Terminals Up to 5 relays (independently configurable for process variables, Hold & Cleaning functions)
Electromechanical relay SPDT and SPST contact outputs
5A – 250 Vac; 5A – 30 Vdc (resistive load)
Fuse protected
Alarm Relay Set Point Up to 5 relays (independently configurable for process variables, Hold & Cleaning functions)

Electromechanical relay SPDT and SPST contact outputs
5A – 250 Vac; 5A – 30 Vdc (resistive load)
Fuse protected
Over Dosing Control yes
System Error yes
Analog Ouput Signal 2 or 4 independent, galvanically isolated outputs
0 – 22 mA configurable as
Analog Ouput Accuracy ±2% full scale
Digital Input Signal independent, galvanically isolated inputs (configurable for Hold & Cleaning functions)
On state
Digital Output Signal RS485
Backlight yes
Power Consumption 15VA
Enclosure *Single case ½ DIN, type NEMA4X, IP65 ingress protection
Installation Category II
Panel Cutout 1/2 DIN (brackets ordered seperately)
Input Channels one digital input with RS485 interface
pH Electrode HI10X6 series – pH and Temperature (ordered seperately)
ORP Electrode HI20X4 series – ORP and Temperature (ordered seperately)
Logging Type Interval log, up to 100 files, maximum 8600 records on each stored file.
When the maximum limit of 100 stored files is reached, the most recent file will automatically erase the oldest one.
Event log, maximum 100 records. When the maximum limit i
Connectivity RS485 serial port - Remote monitoring and control
USB-C port - Retrieve log files and firmware upgrading
GLP yes
Calibration Timeout Reminder yes
Analog Output up to 4 based on configuration ordered
Display Graphic LCD, 128 x 64 pixel B/W with backlight
Power Supply 100 – 240 Vac ±10%; 50/60 Hz; 15VA; fuse protected (2A, 250V slow blow fuse)
Environment -20 to 50 ºC (-4 to 122 ºF); maximum 100% RH non-condensing
IP Rating IP65
Dimensions Width 144.0 mm (5.7”) x Height 144.0 mm (5.7”) x Depth 151.3 mm (6.0”)
Weight Approximately 1.6 kg (3.5 lb.)
Notes *For a water tight seal, tighten the front four screws on the front casing to 13.3 lbf·in (1.5 N·m, maximum 2.0 N·m), of torque.

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Subscribe Newsletter