Hanna Instruments (M) Sdn Bhd added new photo in Electrodes & Probes - pH
Jun 13, 2024 at 05:14 pm —
FC101D Foodcare pH/Temperature Electrode for Milk

FC101D Foodcare pH/Temperature Electrode for Milk

RM 1,032.00

FC101D is a specialized electrode that offers numerous features that improve pH testing for milk producers design to be used with the HI99162 Foodcare Meter. An integrated temperature sensor allows for temperature compensated pH measurements without the need for a separate temperature probe. The contact between the bulb's large surface area and the milk sample ensures a stable calibration and measurement. Durable PVDF plastic body ensures pH measurements can be safely taken on the dairy farm or production floor. Open junction design that resists clogging from milk-based solids. The HI98162 uses the FC101D amplified pH electrode with PVDF body. This specialized electrode offers numerous features that improve pH testing for milk producers. An integrated temperature sensor allows for temperature compensated pH measurements without the need for a separate temperature probe. The contact between the bulb¡¯s large surface area and the milk sample ensures a stable calibration and measurement. An integral part of any pH electrode is the reference junction. The reference junction is a part of the electrode that allows for the flow of ions located in the reference cell into the sample being tested. It is vital that this flow occurs in order to complete an electrical circuit, which ultimately determines the pH value. Any clogging of the junction will prevent completion of the circuit, resulting in readings that are erratic or constantly drifting. The FC101D probe utilizes a secondary reference chamber with ceramic outer junction allowing aqueous silver free electrolyte to flow slowly through the porous ceramic frit providing accurate readings for aqueous samples. The durable PVDF body of the FC101D ensures pH measurements can be safely taken on the dairy farm or production floor. The components of the electrode are also able to withstand a wider range of temperatures to allow for accuracy during stages such as pasteurization, which requires heating to temperatures near 72¡ãC (161¡ãF). More Information SKU FC101D Product Name Foodcare pH/Temperature Electrode for Milk – FC101D Quote Required Yes Measurement Range pH Temperature Range 0 to 80¡ãC (32 to 176¡ãF) - GP Reference Cell Type double, Ag/AgCl Junction Type/Flow Rate ceramic, single / 15-20 µL/h Type of Electrolyte 3.5M KCl Tip / Shape spheric (dia Max. Pressure 0.1 bar Temperature Sensor yes Connector Type DIN Amplifier yes Recommended Use milk (HI99162 Foodcare pH / Temperature Meter for Milk) read more
Hanna Instruments (M) Sdn Bhd added 5 new photos in Solutions - CAL Check Standards
Jun 12, 2024 at 04:06 pm —
HI7014-11 Pool Line Free Chlorine Checker HC Calibration Check Set
HI7754-11 Pool Line Alkalinity Checker HC Calibration Check Set
HI7214-11 Pool Line Iron Checker HC Calibration Check Set
HI7134-11 Pool Line Phosphate Low Range Checker® HC Calibration Check Set
HI7024-11 Pool Line High Range Copper Checker HC Calibration Check Set
Hanna Instruments (M) Sdn Bhd added new photo in Accessories - Photometers
Jun 12, 2024 at 09:30 am —
HI731335 Caps for Glass Cuvette Used with HI96 Series Portable Photometers (4 pcs)

HI731335 Caps for Glass Cuvette Used with HI96 Series Portable Photometers (4 pcs)

RM 80.00

The HI731335 are the replacement caps that screw on the glass cuvettes used with the HI96 series portable photometers. Each cap has a locking indexing tab that ensures the cuvette is inserted into the photometer in the same position. The caps are also used to block any light that would interfere with the optically based measurement. The HI731335 includes 4 caps. Locking index tab for proper alignment in the photometer Light blocking to prevent stray light from entering When using a photometer it is important to insert the cuvette in the same position when performing a blank measurement (zero) and a read with reacted sample in order to maintain a consistent path length in accordance with the Beer-Lambert Law (see below).  The HI731335 have a locking index tab in the cap that fits with the HI96 series photometers to ensure that the cuvette is inserted in the same orientation each time.   The quantity of radiation absorbed is given by the Beer-Lambert Law: A = log Io/I   Absorbance is also given by: A= ¦Å¦Ë • C • l where: A is a dimensionless number ¦Å¦Ë the proportionality constant, is called the molar extinction coežcient or molar absorptivity; it is a constant for a given substance, provided the temperature and wavelength are constant [L/(mol•cm)] C is the concentration of the substance (mol/liter) l is theoptical distance light travels through sample (cm) The HI731335 are the replacement caps for glass cuvettes that are supplied with all HI96 series portable photometers. The are also designed to keep any stray light from entering the sample cuvette holder of the optically based system.      More Information SKU HI731335 Product Name Caps for Glass Cuvette Used with HI96 Series Portable Photometers (4 pcs) - HI731335 Quote Required Yes Notes Package Quantity 4 read more
Hanna Instruments (M) Sdn Bhd added 2 new photos in Accessories - Lab Supplies
Jun 12, 2024 at 09:26 am —
HI920013 USB Cable for PC Connection
HI7408015 Replacement Battery for HI801
Hanna Instruments (M) Sdn Bhd added 6 new photos in Accessories - Multiparameter Meters
Jun 12, 2024 at 09:08 am —
Hanna Instruments (M) Sdn Bhd added 7 new photos in Accessories - Turbidity Meters
Jun 12, 2024 at 08:52 am —
Hanna Instruments (M) Sdn Bhd added 5 new photos in Accessories - Thermometers
Jun 12, 2024 at 08:42 am —
HI710027 Shockproof Rubber Boot (Blue)
HI141001 Infrared Transmitter for Temperature Dataloggers
HI766EX Extension Cable for Thermocouple Probes
HI766HD Interchangeable Handle for Thermocouple Probes
HI710007 Shockproof Rubber Boot (Blue)
Hanna Instruments (M) Sdn Bhd added 14 new photos in Accessories - Lab Supplies
Jun 11, 2024 at 11:50 am —
Hanna Instruments (M) Sdn Bhd added 5 new photos in Accessories - Dissolved Oxygen
Jun 4, 2024 at 09:06 am —
HI764080A/P edge Dissolved Oxygen Spare Screw Cap Membranes
HI76483A/P Membrane Caps for HI76483 DO Probe
HI76409-0 Protective Sleeve for HI76409 Probe Series
HI76409A/P Spare Dissolved Oxygen Screw Cap Membranes For Galvanic Sensors
HI76407A/P Spare Dissolved Oxygen Screw Cap Membranes
next page