*HI3897 Olive Oil Acidity Test Kit

Previous 82 / 86 Next

*HI3897 Olive Oil Acidity Test Kit Chemical Test Kits *HI3897 Olive Oil Acidity Test Kit Chemical Test Kits *HI3897 Olive Oil Acidity Test Kit Chemical Test Kits *HI3897 Olive Oil Acidity Test Kit Chemical Test Kits *HI3897 Olive Oil Acidity Test Kit Chemical Test Kits *HI3897 Olive Oil Acidity Test Kit Chemical Test Kits
RM 1,037.00
1 kg
In Stock


Download Files

manhi_3897.pdf (521.38 KB)
The HI3897 Olive Oil Acidity Test Kit is a user-friendly way to determine the percent acidity of your olive oil. The percent acidity of olive oil is a direct indicator of its quality, classification, and freshness. Normally, testing acidity is a complicated process requiring the use of various chemicals in a laboratory environment. The HI3897 kit utilizes a titration method where the endpoint is visually determined when the color changes from yellow-green to pink. With the Olive Oil Acidity Test Kit, it is possible to test the quality of olive oil at various stages of processing and storage to monitor and maintain the highest quality.
  • Calibrated dosing syringe
  • Single use solvent bottles
  • Speedsafe™ magnetic stirrer

Details

The HI3897 Olive Oil Acidity Test Kit is a comprehensive kit designed to measure the percent acidity of your olive oil. With initial dissolution in an organic solvent, the olive oil sample is titrated with sodium hydroxide until a color change is observed. There are six bottles of organic solvent supplied in the kit, each of them suitable for one titration test. The basic titrant solution is added dropwise to the sample by a plastic calibrated syringe and tapered tip.The HI3897 is a perfect solution for olive oil producers who appreciate a speedy, accurate way to determine the quality of their product.

Features at-a-glance

  • Complete testing setup

    • All required materials are included with the test kit, such as the one-time-use solvent bottles, titrant solution, calibrated syringe, and magnetic stirrer.

  • High resolution

    • Readings from 0.00 to 1.00% acidity are determined to 0.01% (0.01 mL) resolution.

  • Replacement reagents available

    • There is no need to buy a new kit when reagents are exhausted. A new reagent kit containing titrant solution and organic solvent bottles for 10 tests can be ordered individually.

 

Significance of Use

Acidity (as % oleic acid) is the most fundamental measurement of olive oil. It is the primary indicator of olive oil purity and freshness. The quality of olive oil is directly related to the degree of breakdown of the fatty acids in the oil. As the bound fatty acids break down, free fatty acids are formed, increasing the percent acidity of the oil. Acidity is a measure of the free fatty acids present in the oil, which is directly related to its purity.

The quality of olive oil can be adversely a™ffected during either maturation or by environmental conditions. Mishandling, processing, and bruising during harvesting can also contribute to a breakdown of fatty acids and an increase in free acidity. Improper and/or long-term storage can cause olive oil to break down and become rancid. Regular acidity testing is the best way to ensure and maintain quality and freshness.

Acidity is used to discriminate an extra virgin olive oil from all other olive oils. According to the CEE 2568/91 regulation, olive oil is considered extra virgin when its acidity level is below 1%. A low acidity value also indicates a natural extraction process occurred soon after olive harvesting.

 

• Extra Virgin Olive Oil: Acidity <1%

“Perfect flavor and odor” with a maximum acidity of 1 g/100 g oleic acid

 

• Virgin Olive Oil: Acidity 1 - 2%

“Perfect flavor and odor” with a maximum acidity of 2 g/100 g oleic acid

 

• Ordinary Virgin Olive Oil: Acidity 2 - 3.3% (tolerance of 10%)

“Good flavor and odor” with a maximum acidity of 3.3 g/100 g oleic acid

 

• Virgin Lampante Olive Oil: >3.3% Not fit for human consumption

“Off flavor and odor” with a maximum acidity of > 3.3 g/100 g oleic acid
 

Acidity Specifications

Range 0 to 1 % acidity (as oleic acid)
Resolution 0.01 mL = 0.01%
Method titration
Sample Size 4.6 mL or 4 g
Number of Tests 6

Magnetic Stirrer Specifications

Maximum Stirring Capacity 1 liter (0.26 gallons)
Min. Speed Range 100 rpm
Max. Speed Range 1000 rpm
Installation Category II
Cover Material ABS plastic
Environment 0 to 50°C (32 to 122°F), RH max 95%

Specifications

 

CTK Type Titration
Dimensions HI3897: 112 x 390 x 318 mm (4.4 x 15.4 x 12.5’’)
HI180: dia. 137 mm x 51 mm (h) (5.39 x 2”)
Weight 640 g (1.4 lbs.)
Ordering Information HI3897 is supplied with 6 ready-to-use bottles of organic solvent (40 mL each) with 1 magnetic bar each, HI180I/MB magnetic stirrer, 5.0 mL calibrated syringe for oil dosing, 1.0 mL calibrated syringe for titrant dosing with tip, titrant solution (20 mL bottle), rugged carrying case, and instruc

 

Manual:

pdf manHI_3897

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Recent Updates
Subscribe Newsletter