*HI3822 Sulfite Chemical Test Kit

Previous 74 / 86 Next

*HI3822 Sulfite Chemical Test Kit Chemical Test Kits
RM 508.00
1 kg
In Stock


Download Files

3822.pdf (241.83 KB)
The HI3822 is a chemical test kit that uses a titrimetric method to measure sulfite as sodium sulfite (Na2SO3). The HI3822 is supplied complete with all of the reagents and equipment necessary to perform approximately 110 tests.

  • Pre-made
  • eagents for ease of use
  • All reagents marked with expiration date and lot number for traceability
  • Manual titration performed with starch indicator

Details

The HI3822 is a chemical test kit that determines the sulfite concentration in two ranges: 0 to 20 mg/L and 0 to 200 mg/L Na2SO3. The HI3822 is supplied with all of the necessary reagents and equipment to perform the analysis. The test kit contains enough reagents for perform approximately 110 tests.

Features at-a-glance

  • Complete setup

    • All required materials are included with the test kit, such as the sample beakers, indicator and reagent bottles, and calibrated syringe.

  • High resolution

    • Readings from 0 to 20 mg/L are determined to 0.2 mg/L resolution.

    • Readings from 0 to 200 mg/L are determined to 2 mg/L resolution.

  • Replacement reagents available

    • There is no need to buy a new kit when reagents are exhausted. The HI3822-100 can be ordered to replace the reagents supplied with the kit.


Significance of Use

There are many reasons to monitor the concentration of sulfite in water. In boiler feed and effluent waters, a sulfite concentration of approximately 20 mg/L must be maintained to prevent pitting and oxidation of metal components. A high level of sulfite results in a lowered pH, thus promoting corrosion. The monitoring of sulfite is important in environmental control as well. Sulfite ions are toxic to aquatic lifeforms; the chemical demand that sulfide produces on oxygen in water can destroy the delicate ecological balance of lakes, rivers and ponds.

Specifications

 

Range 0 to 20 mg/L (ppm) Na₂SO₃; 0 to 200 mg/L (ppm) Na₂SO₃
Resolution 0.2 mg/L (0 to 20 mg/L range); 2 mg/L (0 to 200 mg/L range)
Method iodometric
Number of Tests 110
CTK Type Titration
Weight 910 g
Ordering Information HI3822 test kit comes with 30 mL sulfamic acid solution, 30 mL EDTA reagent, 15 mL sulfuric acid solution, 10 mL starch indicator, 120 mL titrant solution, 20 mL calibrated vessel, 50 mL calibrated vessel, and calibrated syringe with tip.

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Recent Updates
Subscribe Newsletter