Hanna Instruments (M) Sdn Bhd added new photo in Monitors & Dataloggers
12 hours ago —
HI147-00 Checkfridge™ Remote Sensor Thermometer

HI147-00 Checkfridge™ Remote Sensor Thermometer

RM 352.00

The HI147 is a remote temperature sensor ideal for monitoring in food care environments. It contains magnets for easy placement on a metal surface and delivers high accuracy measurements over a wide temperature range. CAL Check™ Magnetized Clear Display The HI147 is a remote temperature ideal for monitoring in food care environments. It contains magnets for easy placement on a metal surface and delivers high accuracy measurements over a wide temperature range. The thermometer*s unique CAL Check™ feature allows for an internal calibration of the device with the flick of a switch, thereby alleviating the time preparing an ice bath.   Features at-a-glance CAL Check™  - The thermometer*s unique CAL Check™ feature allows for an internal calibration of the device with the flick of a switch, thereby alleviating the time preparing an ice bath. Magnetized - Two magnets located on the back of the device all for easy placement on the outside of a refrigerator or metal cabinet. Food Compatible Cable - The thermometer is specially designed with a food compatible cable for continuous monitoring of temperature in food care environments.   SKU HI147-web Product Name Checkfridge™ Remote Sensor Thermometer - HI147 Quote Required Yes Temperature Range HI147-00 -50.0 to 150.0∼C HI147-01 -58.0 to 302.0∼F Temperature Resolution HI147-00 0.1∼C HI147-01 0.1∼F (-58.0 to 199.9∼F) 1∼F (200 to 302∼F) Temperature Accuracy HI147-00 ㊣0.3∼C (-20 to 90∼C); ㊣0.5∼C (outside) HI147-01 ㊣0.6∼F (-4 to 194∼F); ㊣1∼F (outside) Battery Type/Life 1.5V AAA / approximately 3 years of continuous use Environment 0 to 50∼C (32 to 122∼F); RH max 95% Dimensions 93 x 39 x 31 mm (3.7 x 1.5 x 1.2**) Weight 60 g (2.1 oz.) Ordering Information HI147 is supplied with battery and instructions.   read more
HI6421P Advanced Dissolved Oxygen Benchtop Meter with Polarographic DO Probe
HI6421 Advanced Dissolved Oxygen Benchtop Meter with Optical DO Probe (opdo®)
HI6321 Advanced Conductivity Benchtop Meter

HI6321 Advanced Conductivity Benchtop Meter

RM 5,807.00

HI6321 is a streamlined Conductivity/Resistivity/TDS/Salinity/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module. HI6321 is a streamlined Conductivity/Resistivity/TDS/Salinity/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module. Compact and easy to operate, the HI6321 includes Hanna*s HI7631233 four-ring conductivity/ resistivity/TDS/salinity probe. Recommended for a wide range of industrial process water applications, HI7631233 provides stable measurements over a wide measurement range and does not require frequent calibrations. An integral temperature sensor measures the process temperature and adjusts the measured conductivity to a reference temperature by applying specialized compensation algorithms: Linear: appropriate when it is assumed that the temperature coefficient of variation has the same value for all measurement temperatures. Standard: appropriate for high-purity water measurements and documented in ASTM Standard D5391-14. This setting should be used for >1Mohm.cm resistivity measurements. Natural: appropriate for natural ground, well, or surface water (or water with similar composition) in accordance with ISO7888 standard. The result is reliable electrolytic conductivity (EC), TDS (Total Dissolved Solids), resistivity, or Seawater Salinity in percent, psu, or ppt units. TDS is a calculated value based on the conductivity of the solution (TDS = factor x EC25). A TDS factor is a conversion factor used to change an EC measurement to a ppm measurement. Sal psu: The practical salinity of seawater relates the ratio of electrical conductivity of a normal seawater sample at 15 ∼C and 1 atmosphere to a potassium chloride solution (KCl) with a mass of 32.4356 g/Kg water at the same temperature and pressure. Under these conditions the ratio is equal to 1 and S=35. The practical salinity scale may be applied to values 0 through 42.00 psu at temperatures between 0 to 35 ∼C. Sal ppt: measurements expressed in ppt are based on the Natural Seawater Scale that extends from 0.00 to 80.00 g/L and covers 10 to 31 ∼C temperature range. It determines the salinity based upon a conductivity ratio of sample to standard seawater at 15 ∼C and an approximate salinity value of 35 in seawater. Sal %: in this scale 100% salinity is equivalent to roughly 10% solids. User interface 7-inch capacitive touch screen with multi-touch support Capacitive touch back, home and system menu keys User-friendly icons and symbols allow users to easily navigate and interpret the instrument functions. The user can select between five different views: Basic measurement configuration Simple GLP with calibration information Full GLP with electrode status and calibration point details Live updated, interactive graph Tabulated data with date, time, and notes Measurement Measure 米S/cm, mS/cm (Conductivity); 次·cm, k次·cm, M次·cm (Resistivity); ppm, ppt (TDS); ppt, PSU, % (Salinity) with temperature Application-specific profiles allow quick and direct measurement without the need to update the sensor and system settings Active log during measurement o Measurement stability indicator (using the Stability Criteria setting) Reading modes: direct and direct/autohold Temperature compensation can be Automatic or set manually Audible and/or alarm messages for measurements outside of predefined limits Galvanic isolation for conductivity measurement Calibration Standard single point salinity calibration in 100% salinity standard, with the reading salinity scale set to % Standard single or multiple conductivity calibration with standards Non-volatile memory saves data and settings Logging Data log collection of at least 1,000,000 data points (with time and date stamp) Logging types: manual, automatic, autohold Sample ID for manual and Autohold data Connectivity features & services Transfer logged data to a USB thumb drive Log files that include measurements and calibration data (as .csv file) FTP and email for log export via Ethernet and Wi-Fi connection o USB type A for USB stick, keyboard, and printer USB type C for USB stick and PC connection SKU HI6321 Product Name Advanced Conductivity Benchtop Meter - HI6321 Quote Required Yes Conductivity Range 0.000 to 9.999 米S/cm; 10.00 to 99.99 米S/cm; 100.0 to 999.9 米S/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm Conductivity Resolution 0.001 米S/cm; 0.01 米S/cm; 0.1 米S/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm Conductivity Accuracy ㊣1 % of reading (㊣0.01 米S/cm) Resistivity Range 1.0 to 99.9 次·cm; 100 to 999 次·cm; 1.00 to 9.99 K次·cm; 10.0 to 99.9 K次·cm; 100 to 999 K次·cm; 1.00 to 9.99 M次·cm; 10.0 to 100.0 M次·cm Resistivity Resolution 0.1 次·cm; 1 次·cm; 0.01 K次·cm; 0.1 K次·cm; 1 K次·cm; 0.01 M次·cm; 0.1 M次·cm Resistivity Accuracy ㊣1 % of reading (㊣1 次·cm) Total Dissolved Solids (TDS) Range 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor) Total Dissolved Solids (TDS) Resolution 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt Total Dissolved Solids (TDS) Accuracy ㊣1 % of reading (㊣0.01 ppm) Salinity Range 0.00 to 42.00 PSU - Practical Scale 0.00 to 80.00 ppt - Natural Sea Water 0.0 to 400.0 % - Percent Scale Salinity Resolution 0.01 for Practical Scale / Natural Sea Water 0.1 % for Percent Scale Salinity Accuracy ㊣1 % of reading Temperature Range −20.0 to 120.0 ∼C −4.0 to 248.0 ∼F 253.0 to 393.0 K Temperature Resolution 0.1 ∼C; 0.1 ∼F; 0.1 K Temperature Accuracy ㊣0.2 ∼C; ㊣0.4 ∼F; ㊣0.2 K Conductivity Calibration points Auto standard recognition / User standard, Single Point / Multi Point calibration Conductivity Calibration Standard solutions 84.00 µS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm Conductivity Calibration Reminder Disabled Daily Salinity Calibration 1 point for Percent Scale Temperature Compensation Automatic or Manual Reading Modes Direct Direct/Autohold Reading Stability criteria Accurate Medium Fast Reading Sampling rate 1000 ms EC Views Basic Measurement (EC, Resistivity, TDS, Salinity, Temperature) Stability status EC Views Simple GLP Basic view information Last calibration date, offset EC Views Full GLP Simple GLP information and calibration point details EC Views Table Measurements updated every second are displayed in table EC Views Graph (Plot) Measurement versus time graph can be panned or zoomed (pinch-to-zoom technology) Logging Type Automatic, Manual, Autohold Logging Number of records 50 000 maximum per file Stores at least 1 000 000 data points per user Logging Automatic interval 1, 2, 5, 10, 30 seconds 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes Logging Sample ID Incremental mode Logging Export option .csv file format Users Up to 9 users and the default administrator account Connectivity USB-A 2 ports for keyboard input or USB thumb drive Connectivity USB-C 1 port for PC connectivity and USB-C type thumb drive Connectivity Wi-Fi & Ethernet FTP Web server Log transfer and download Email Connectivity RS232 Connecting peripherals Power supply DC adapter 100-240AC to 24VDC 2.5A Environment 0 - 50 ∼C / 32 - 122 ∼F / 273 - 323 K maximum 95% RH non-condensing Dimensions 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 ※) Weight Approximately 1.2 kg (26.5 lbs.) read more
Hanna Instruments (M) Sdn Bhd added new photo in Benchtop Meters - pH/ORP
13 hours ago —
HI3220 pH/ORP/Temperature Bench Meter with Calibration Check

HI3220 pH/ORP/Temperature Bench Meter with Calibration Check

RM 2,323.00

HI3220 is a professional pH bench meter with a graphic LCD designed to provide high accuracy and ease of use both in the laboratory as well as in harsh industrial conditions. This instruments is a single input model measuring pH, ORP, and temperature utilizing a single channel. A Relative mV feature is also available. Main Features: Single input channel Up to 5 point pH calibration with 7 standard buffers and 5 custom buffers to choose from Messages on the graphic LCD for an easy and accurate calibration Diagnostic features to alert the user when the electrode needs cleaning Three types of logging modes (for pH and mV) Stability logging Interval logging Log-on-demand Relative mV measurements Log on demand up to 200 samples Log interval with log on stability feature up to 600 records Auto Hold feature, to freeze first stable reading on the LCD GLP feature, to view last calibration data for pH or Rel mV PC Interface More Information SKU HI3220 Product Name pH/ORP/Temperature Bench Meter with Calibration Check - HI3220 Quote Required Yes pH Range -2.0 to 20.0 pH / -2.00 to 20.00 pH / -2.000 to 20.000 pH pH Resolution 0.1 pH / 0.01 pH / 0.001 pH pH Accuracy ㊣0.01 pH / ㊣0.002 pH pH Calibration Up to 5 points / 7 standard buffers (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) / 5 custom buffers ORP Range ㊣2000.0 mV ORP Resolution 0.1 mV ORP Accuracy ㊣0.2 mV Temperature Range -20.0 to 120.0 ∼C (-4.0 to 248.0 ∼F) Temperature Resolution 0.1 ∼C (0.1 ∼F) Temperature Accuracy ㊣0.2 ∼C (㊣0.4 ∼F) (excluding probe error) Rel mV offset range ㊣2000 mV Slope calibration From 80 to 110% Temperature compensation Manual / Automatic Electrode Hanna BNC connection pH / ORP electrodes Temperature probe RCA Connection / Recommended option LOG on demand 200 samples Lot logging 5, 10, 30 seconds / 1, 2, 5, 10, 15, 30, 60, 120, 180 minutes / AutoEnd (maximum 600 samples) Environment 0 to 50 ∼C (32 to 122 ∼F) / max. RH 55% non-condensing Power Supply 12 Vdc power adapter PC interface opto-isolated USB Dimensions 235 x 207 x 110 mm (9.2 x 8.14 x 4.33 in.) Weight(meter only) 1.8 Kg (4.1 lbs)   read more
Hanna Instruments (M) Sdn Bhd added new photo in Benchtop Meters - ISE
14 hours ago —
HI5522-02 Laboratory Research Grade Benchtop pH/mV/ISE and EC/TDS/Salinity/Resistivity Meter

HI5522-02 Laboratory Research Grade Benchtop pH/mV/ISE and EC/TDS/Salinity/Resistivity Meter

RM 6,742.00

The HI5522 is an advanced research grade benchtop pH/mV/ISE/EC/TDS/Salinity/Resistivity meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity. The HI5522 is rich in features including ISE incremental methods, data logging, alarm limits, comprehensive GLP, and many more while retaining simplicity in use with both dedicated key for routine operation and virtual keys that guide the user through setup options. The HI5522 ensures confidence in pH measurements with the exclusive Hanna Instruments CAL Check™ feature that alerts the user to potential problems during calibration including if the buffer is contaminated or the probe needs to be cleaned. Capacitive touch keypad Two independent channels ISE choice of concentration units and incremental methods The HI5522 is an advanced research grade benchtop pH/ORP/ISE and EC/TDS/Salinity/Resistivity meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity. The HI5522 is a two-channel meter that allows for simultaneous measure of pH, ORP, or ISE on one channel and EC, TDS, Salinity, or Resistivity on the other.  Channel 1 has a BNC connection for use with the expansive line of pH, ORP, and ISE electrodes that Hanna Instruments offers. The meter is supplied with the HI1131B glass body, double junction, combination pH electrode that operates over a wide temperature range from 0 to 100 ∼C.   All readings are automatically compensated for temperature variations with the separate HI7662-T temperature probe or from the built in temperature sensor of the conductivity probe on Channel 2.  The HI5522 is supplied with the HI76312 four-ring conductivity probe that operates over a wide range from 0.000 米S/cm to 1000.0 mS/cm*. The meter can be set to auto-ranging in which the meter chooses the appropriate conductivity range from seven ranges or fixed range in which the meter will only display reading in 米S/cm or mS/cm.  All readings are automatically compensated for temperature variations with a built in temperature sensor. The temperature correction coefficient is adjustable from 0.00 to 10.00 %/∼C. As a pH meter the HI5522 can be calibrated up to five points with a choice of eight pre-programmed buffers or five custom buffers. The HI5522 features Hanna*s exclusive CAL Check™ to alert the user of potential problems during the pH calibration process.  Indicators displayed during calibration include ※Electrode Dirty/Broken§ and ※Buffer Contaminated.§ The overall probe condition based on the offset and slope characteristic of the electrode is displayed as a percentage after calibration is complete. In ISE mode the HI5522 can be calibrated up to five points with a choice of five fixed standards or five user defined in any concentration unit. The calibration data including date, time, standards used and slope can be viewed at any time along with the current measurement by selecting the Good Laboratory Practice (GLP) display option. As an EC/TDS/Salinity/Resistivity meter the HI5522 can be calibrated up to four points with a choice of six pre-programmed conductivity standards or user defined custom standards. Resistivity, TDS, Practical Salinity (PSU) and Natural Seawater Scale are calibrated through conductivity. The % NaCl is calibrated to single point with the HI7037 salinity standard. The calibration data including date, time, and standards used, offset and cell factor can be accessed at any time along with the current measurement by selecting the Good Laboratory Practice (GLP) display option. For the measurement of high purity water used in pharmaceutical manufacturing, the HI5522 is programmed with the three stages of the USP <645> method.  Once a stage is met a report is generated and can be saved. Up to 200 reports can be stored and transferred to a Windows® compatible computer using a USB cable and software (sold separately). Three selectable logging modes are available: automatic, manual and AutoHold logging. Up to 100,000 data points can be recorded in 100 lots with 50,000 records max/lot on each channel and exported to a computer for data review and storage.   Features at-a-glance Highly Customizable User Interface – The user interface of the HI5522 allows the user to show measurements in various modes: basic measurement with or without GLP information, real-time graphing, and logging data. Calibration stability criteria can be adjusted from fast, moderate, and accurate. Programmable alarm limits can be set to inside or outside allowable limits. Color Graphic LCD – The HI5522 features a color graphic LCD with on-screen help, graphic, and custom color configurations. The display allows for real-time graphing and the use of virtual keys provide for an intuitive user interface. Capacitive Touch – The HI5522 features sensitive capacitive touch buttons for accurate keystrokes when navigating menus and screens. There are four dedicated keys that are used for routine operations including calibration and switching measurement modes and four virtual keys that change based upon use. The capacitive touch technology ensures the buttons never get clogged with sample residue. Four Ring Conductivity Probe – All readings are performed with the HI76312 four-ring conductivity probe that has a built in temperature sensor for automatic temperature correction.  The four rings are made with platinum and the body of the electrode is made of Polyetherimide (PEI) plastic that is resistant to many harsh chemicals.  The four-ring design allows for this probe to be used over a wide range of measurements. Choice of Calibration – Automatic buffer recognition, semiautomatic, and direct manual entry pH calibration options are available for calibrating up to five points, from a selection of eight standard buffers and up to five custom buffers.  For the conductivity channel the calibration can be set to automatic standard recognition or user entry along with a choice of single or multi-point. Calibration can be performed up to four points when multi-point is selected. CAL Check™ – CAL Check™ alerts users to potential problems during the calibration of the pH electrode. Indicators include ※Electrode Dirty/Broken,§ ※Buffer Contaminated,§ electrode response timeand the overall probe condition as a percentage that is based on the offset and slope characteristics. GLP Data – HI5522 includes a GLP Feature thatallows users to view calibration data and calibration expiration information at the touch of a key. Calibration data include date, time, standards used for calibration. ISE Measurement with Choice of Concentration Units – The HI5522 allows for calibration and readings in choice of concentration units. The choices of concentration units include ppt, g/L, mg/mL, ppm, mg/L, 米g/L, ppb, 米g/L, mg/mL, M, mol/L, mmol/L, %w/v and a user-defined unit. ISE Measurement with Incremental Methods – The known addition, known subtraction, analyte addition, and analyte subtraction incremental methods are pre-programmed into the HI5522.  Simply follow the on screen guided procedure and the meter will perform the calculation automatically allowing for a higher level of accuracy to be obtained as compared to a direct ISE measurement. Data Logging – Three selectable logging modes are available on the HI5522: automatic, manual, and AutoHold logging. Automatic and manual logs up to 100 lots with 50,000 records max/lot, with up to 100,000 total data points. Automatic logging features the option to save data according to sampling period and interval. Data Transfer – Data can be transferred to a PC with USB cable and HI92000 software (both sold separately). Contextual Help – Contextual help is always available through a dedicated ※HELP§ key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration.  The help information displayed is relative to the setting/option being viewed. CAL Check alert to potential problems during calibration Comprehensive GLP Data Real time logging   More Information SKU HI5522-02 Product Name Laboratory Research Grade Benchtop pH/mV/ISE and EC/TDS/Salinity/Resistivity Meter - HI5522 Quote Required Yes pH Range -2.0 to 20.0 pH / -2.00 to 20.00 pH / -2.000 to 20.000 pH pH Resolution 0.1 pH / 0.01 pH / 0.001 pH pH Accuracy ㊣0.1 pH / ㊣0.01 pH / ㊣0.002 pH ㊣ 1LSD pH Calibration Up to five-point calibration, eight standard buffers available (pH 1.68, 3.00, 4.01, 6.86, 7.01,9.18, 10.01, 12.45), and five custom buffers pH Temperature Compensation automatic or manual from -20.0 to 120.0 ∼C mV Range ㊣2000.0 mV mV Resolution 0.1 mV mV Accuracy ㊣0.2 mV ㊣ 1LSD mV Relative Offset ㊣2000.0 mV ISE Range e.g. 10-7 to 10M/ 0.005 to 105 ppm/ 5·10–7 to 5·107 conc ISE Resolution 1 conc./ 0.1 conc. / 0.01 conc. / 0.001 conc ISE Accuracy ㊣0.5% (monovalent ions); ㊣1% (divalent ions) ISE Calibration Up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five custom solutions EC Range 0.000 to 9.999 米S/cm, 10.00 to 99.99 米S/cm, 100.0 to 999.9 米S/cm, 1.000 to 9.999 mS/cm, 10.00 to 99.99 mS/cm, 100.0 to 1000.0 mS/cm actual EC* EC Resolution 0.001 米S/cm, 0.01 米S/cm, 0.1 米S/cm, 1 米S/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm EC Accuracy ㊣1% of reading (㊣0.01 米S/cm) EC Calibration automatic standard recognition (0.000 米S/cm, 84.00 米S/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm) or user standard; single point or multi-point calibration TDS Range 0.000 to 9.999 ppm, 10.00 to 99.99 ppm, 100.0 to 999.9 ppm, 1.000 to 9.999 ppt, 10.00 to 99.99 ppt, 100.0 to 400.0 ppt actual TDS* (with 1.00 factor) TDS Resolution 0.001 ppm, 0.01 ppm, 0.1 ppm, 1 ppm, 0.001 ppt, 0.01 ppt, 0.1 ppt TDS Accuracy ㊣1% of reading (㊣0.01 ppm) EC/TDS Temperature Compensation Disabled / Linear / Non linear (natural water) Temperature Correction Coefficient 0.00 to 10.00 %/∼C Reference Temperature 5.0 ∼C to 30.0 ∼C Cell Constant 0.0500 to 200.00 Cell Type 4 cells Salinity (% NaCl) Range 0.0 to 400.0% Salinity (% NaCl) Resolution 0.01% Salinity (% NaCl) Accuracy ㊣1% of reading Salinity (PSU) Range 0.00 to 42.00 psu Salinity (PSU) Resolution 0.01 Salinity (PSU) Accuracy ㊣1% of reading Salinity (PSU) Calibration one-point (with HI7037 standard) Salinity Range 0.00 to 80.00 ppt Salinity Resolution (ppt) 0.01 Salinity Accuracy (ppt) ㊣1% of reading Resistivity Range 1.0 to 99.9 次•cm; 100 to 999 次•cm; 1.00 to 9.99 K次•cm; 10.0 to 99.9 K次•cm; 100 to 999 K次•cm; 1.00 to 9.99 M次•cm; 10.0 to 100.0 M次•cm Resistivity Resolution 0.1 次•cm; 1 次•cm; 0.01 K次•cm; 0.1 K次•cm; 1 K次•cm; 0.01 M次•cm; 0.1 M次•cm* Resistivity Accuracy ㊣2% of reading (㊣1 次•cm) Temperature Range -20.0 to 120.0 ºC**; -4.0 to 248.0 ºF**; 253.15 to 393.15 K** Temperature Resolution 0.1 ∼C, 0.1 ∼F, 0.1 K Temperature Accuracy ㊣0.2 ∼C; ㊣0.4 ∼F; ㊣0.2 K (without probe) Input Channels 2 (pH/mV/ISE; Conductivity/Resistivity/TDS/ Salinity) pH Electrode HI1131B glass body pH electrode with BNC connector and 1 m (3.3*) cable (included) EC/TDS Probe HI76312 platinum, four-ring EC/TDS probe with and 1 m (3.3*) cable (included) Temperature Probe HI7662-T stainless steel temperature probe with 1 m (3.3*) cable (included) Logging Type Automatic, Manual, AutoHold Logging Memory Up to 100 lots, 50,000 records max/lot; maximum 100,000 data points / channel Logging Interval 14 selectable between 1 second and 180 minutes Connectivity Opto-isolated USB GLP yes (GLP Channel 1 Calibration Timeout Reminder yes USP Compliant USP <645> Application Profiles Up to 10 (5 for each) Display Color Graphic LCD 240 x 320 pixels, 8 keys capacitive touch keyboard Power Supply 12 VDC adapter (included) Environment 0 to 50∼C (32 to 122∼F; 273 to 323 K), RH max 95% non-condensing Dimensions 160 x 231 x 94 mm (6.3 x 9.1 x 3.7§) Weight 1.2 Kg (2.6 lbs) Ordering Information HI5522 is supplied with HI1131 pH electrode, HI7662-T temperature probe, HI76312 conductivity probe, HI76404W electrode holder, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI700601 electrode cleaning solution sachet (2), HI7082 3.5M KCl electrolyte solution (30 mL), 12 VDC power adapter and instructions. Notes *Uncompensated conductivity (or TDS) is the conductivity (or TDS) value without temperature compensation. read more
HI935001 Foodcare K-Type Thermocouple Thermometer with Detachable Probe
HI935004 Foodcare T-Type Thermocouple Thermometer with Detachable Probe
HI935007 Foodcare K-Type Thermocouple Thermometer with Fixed Attached Probe
HI935008 Foodcare T-Type Thermocouple Thermometer with Fixed Attached Probe
Temperature Datalogger - HI148

Temperature Datalogger - HI148

Easy to handle ! The thermologgers feature extensive memory capacity: 16,000 samples for 1-channel models and 8,000 samples/channel for 2-channel models. Please contact us for more information.
HI148-1 Temperature logger with LCD, 1 channel (internal)

HI148-1 Temperature logger with LCD, 1 channel (internal)

RM 465.00

From storage to shipping, it's important to monitor the temperature of your products to ensure that they are being stored in optimal conditions. Quick to setup, simple to use, the HI148 is a datalogger that is ideal for monitoring and recording temperature in applications such as food processing, transportation, museums, and horticulture. Available with one or two channels, and internal and/or external sensors Multicolor LEDs for logging status Customizable programming using the included software       Thin and Rugged Design The HI148 is housed in a rugged waterproof ABS casing with an IP67 rating which protects against the ingress of dust and submersion in water at a depth of 1 meter for up to 30 minutes. It is compact in size but has a large high contrast display for easy viewing. Each thermologger is supplied with a wall cradle allows for fixed mounting in a location of your choice.   Multiple Sensor Options The HI148 temperature dataloggers are available in four different models. Models are available with one or two channels with a combination of internal and/or external sensors. Loggers with an external temperature sensor feature a stainless steel probe on a 1 m (3.3*) flexible silicone cable.   Programmable LCD Display The HI148 features a large clear LCD display with a wide viewing angle. The LCD is divided into 3 areas: the top displays the status of the datalogger; the middle displays the temperature reading, units, and active channel; the bottom display is user selectable, and can include the minimum and maximum temperature, the high and low alarm thresholds, the current number of samples, and the number of samples outside alarm limits.       PC Connectivity All dataloggers can be programmed and transfer of logged data using a USB-C cable and the HI92148 PC software. Each datalogger is serialized with a unique ID code to track results by meter. The HI92148 PC software is compatible with Windows(R) XP or newer operating system.   Customizable Program Settings The HI148 waterproof thermologgers offer a wide variety of programming options that can be set in the using the HI92148 PC software, including: • Logging start mode that can be delayed by setting a fixed time (1 second to 199 hours ) or started manually by pressing a dedicated button on the back. • Programmable high and low alarm limits with visual LED indicators • Logging and measurement interval (from 1 sec to 24 hours for 1-channel models, and from 2 sec to 24 hrs for 2-channel models) • Each logging session can be assigned an ID number and password.   Data Retrieval and Analysis The thermologgers feature extensive memory capacity: 16,000 samples for 1-channel models and 8,000 samples/channel for 2-channel models. Logged data is displayed as both a table and a graphical representation in the HI92148 software. The graphical representation can be saved as an image file, while the data can also be exported as a spreadsheet for further data analysis.   Waterproof Temperature Data Loggers - HI148 Series   1 Internal Sensor HI148-1 1 External Sensor HI148-2 1 Internal & 1 External Sensor HI148-3 2 External Sensors HI148-4   SKU hi148-web Product Name Temperature Datalogger - HI148 Quote Required Yes Thermistor Temperature Range internal sensor Thermistor Temperature Resolution 0.1 ºC (-40.0 to 100.0 ºC); 0.2 ºC (temp. >100.0 ºC) 0.1 ºF (-40.0 to 190.0 ºF) ; 0.3 ºF (temp. >190.0 ºF) Thermistor Temperature Accuracy ㊣0.5 ºC (-40.0 to 0.0 ºC and 70.0 to 100.0 ºC), ㊣0.4 ºC (0.0 to 70.0 ºC), ㊣1 ºC (>100.0 ºC) ㊣1 ºF (-40.0 to 32.0 ºF and 158.0 to 212.0 ºF), ㊣0.8 ºF (32.0 to 158.0 ºF), ㊣2 ºF (>212.0 ºF) Battery Type/Life 3 x 1.5V AAA / approximately 2 years of use Environment -20.0 to 60.0 ºC (-4.0 to 140.0 ºF); RH 100% Dimensions 107 x 59 x 17 mm (4.2 x 2.3 x 0.7※) Weight 130 g (4.6 oz) Ordering Information HI148 is supplied with logger, AAA alkaline batteries, USB Type A to C cable, instrument quality certificate and instruction manual. Notes HI92148 Windows compatible software can be downloaded free of charge at http read more
Hanna Instruments (M) Sdn Bhd added 2 new photos in Thermometers
17 hours ago —
HI145-00 T-Shaped Celsius Thermometer (125mm)
HI145-01 T-Shaped Fahrenheit Thermometer (125mm)
Hanna Instruments (M) Sdn Bhd added 6 new photos in Thermometers - Testers
17 hours ago —
next page