Hanna Instruments (M) Sdn Bhd
11A, Jalan PJS 11/20,
Bandar Sunway,
46150 Petaling Jaya,
Selangor, Malaysia.
+603-5638 9940
+603-5638 9829
Penang Branch Office
Hanna Instruments (M) Sdn Bhd
N0. 303-2-27, Krystal Point,
Jalan Sultan Azlan Shah,
11900 Sungai Nibong,
Penang, Malaysia.
+604-638 4558
+604-645 4558
penang@hannamalaysia.com

Sabah Branch Office
Hanna Instruments (M) Sdn Bhd

No. 4-1, 1st Floor,
Plaza Kingfisher,
Jalan Plaza Kingfisher 5,
Inanam, 88450 Kota Kinabalu,
Sabah, East Malaysia.
088-382 941
088-382 942
sabah@hannamalaysia.com

Recent Updates

Hanna Instruments (M) Sdn Bhd updated Term & Conditions of Online Purchase page content
Oct 7, 2020 at 04:54 pm —

Term & Conditions of Online Purchase

Authenticity: We guarantee that all advertised products are 100% genuine. Term and Conditions: These are the terms and conditions of our agreement which apply to all purchases of products by you from Hanna Malaysia Online Store and you should read them carefully. We may vary these terms from time to time and therefore you should check them before you make a new purchase. Order: All prices are reflected in Ringgit Malaysia (RM). Delivery is only available within Malaysia. We are under no obligation to accept your order, but would normally do so where the product is available, the order reflects current pricing and your credit card/ debit card payment is approved by your credit card/ debit card company. The display of any product on our website is in no way an offer by us to sell to you. Acceptance of order: We will notify you of our acceptance of your offer to purchase after we receive it and at that point a binding agreement between us will be in place. Only credit and debit cards are accepted as payment for orders via this site. Please ensure an accurate shipping information is supplied. It is your responsibility to check all the details on the order confirmation are correct. Charges incurred due to incorrect details will not be refunded. Delivery: We make every effort to deliver all products within Malaysia within 7 working days of acceptance of your order. Where this is not possible, we will notify you and, unless we state otherwise, ensure that your products are delivered within 28 days from acceptance.  All deliveries will be made to you at the address specified by you in the order. We may, at our discretion and expense, deliver parts of your order separately. Ownership of the products shall pass to you once we have received payment in full. If we cannot deliver the products to you at the address you have specified for any reason (other than when we are at fault), we will notify you and store the products at your risk. The transporter office will not be responsible for the goods if you have signed indicating the goods are received in good condition will make no compensation if goods are damaged during delivery.  Payment:  We take every reasonable care to ensure that your order and subsequent transactions are conducted via a secure link. As we are not responsible for the operation of the secure link we will not, unless we are negligent. If products are not available for any reason after we have accepted your order, we will let you know. For credit card payments, such payment is subject to the approval of the financial institution issuing the credit card and we shall not be liable in any way if such financial institution refuses to accept or honor the credit card for any reason. Warranties: The majority of products will be covered for a period of 12 months from delivery date, from defects in materials and workmanship.  We will replace products (or, where relevant, the faulty part) free of charge. This only applies if the instructions governing the use of the products have been followed. We will not have any further liability in respect of the products. Hanna products are designed and manufactured by our factory to the highest standards for ease of use and installation. If you encounter any difficulties while using your product, we recommend that you first consult the user manual or contact our nearest service centers for support. In the unlikely event of a failure of the product, we will arrange for your product to be serviced free-of-charge within the warranty period provided that the product was used in accordance with the user manual. The warranty excludes, or does not apply: -If the proof-of-purchase (invoice) has been altered or unable to present. -If the serial number on the product has been altered or removed. -If the defect is caused by abuse of the product or mishandling that are not in conformance with the user manual of the product. Should any repair on product has been carried out by unauthorized persons than Hanna service technician. Products Images & Colours: Product images are for illustrative purposes only and may differ from the actual product.  Colours may vary when displayed on different computer screen. Some products may have an associated image or photo. These are for reference only and should be considered illustrative.  Complaint of product images and colours differences is not acceptable. Typographical Errors: In the event, a product is listed at an incorrect price or with incorrect information due to typographical error or error in pricing or product information, we shall have the right to refuse or cancel any orders placed for products listed at the incorrect price. We shall have the right to refuse or cancel any such orders whether or not the order has been confirmed and your credit card has been charged. Product Availability: We cannot guarantee product availability and products, nonetheless, these items may not be available for immediate delivery. We reserve the right, without liability or prior notice, to revise, discontinue, or cease to make available any or all products or to cancel any order. Return Policy: There is no refund or return of the item purchased via the Online Store. All sales are final. Privacy and Policy: We value our customers and their privacy. All personal information is used to ensure efficient processing of your order. This information is used by our staff for contacting and identifying customers and their needs. We will not give, sell, rent, or loan any personally identifiable information to any third party, unless we are legally required to do so or you authorize us to do so. We may change these terms and conditions from time to time without notice to you. Changes will apply to any subsequent orders received.     read more
Hanna Instruments (M) Sdn Bhd added new photo in Testers - pH/EC/TDS
Jun 25, 2020 at 10:20 am —
HI98319 Marine Salinity Waterproof Tester

HI98319 Marine Salinity Waterproof Tester

RM 376.00

HI98319 is a digital salinity tester designed specifically for saltwater aquariums and displays results in parts per thousand (ppt), Practical Salinity Units (PSU), or specific gravity  (S.G.). This waterproof tester uses an amperometric conductivity probe to determine the salt content in the water. This robust tester displays the readings along with temperature on a large LCD. Large Multi-level LCD Displays ppt, PSU or S.G. Exposed Temperature Probe for Fast Response   Simple Two-Button Operation Details Hanna Instruments HI98319 is a salinity tester made specifically for the saltwater aquarium enthusiest and can measure salinity up to 70.00 ppt. The rugged waterproof tester is only 0.7'' thick and extremely ergonomic, fitting comfortably in your hand. The HI98319 keeps things simple with a two-button operation; one for ON/OFF, the other for calibration. The salinity tester features a large multi level LCD which displays either ppt, PSU or specific gravity along with temperature. Temperature can be set to display in oC or oF. An exposed temperature sensor allows for rapid automatic temperature compensated measurements. The LCD screen has stability and calibration tag indicators. A battery percent level indicator is displayed at start up to alert the user of the remaining battery power that is available. Salinity readings are performed by an amperometric graphite probe that resists oxidation, providing better repeatability in measurements. The use of graphite also reduces the polarization effect common with testers that use two stainless steel pins. Calibration is performed by pressing the dedicated calibration button. Once in calibration mode, the probe is placed in 35.00 ppt calibration standard. When the standard value is recognized and stability reached, the meter will automatically accept and store the value. Setup options include an adjustable automatic shut-off in which the meter can be set to turn off after 8 minutes, 60 minutes, or disabled. To enter the setup mode the user presses a button located in the battery compartment. HI98319 waterproof salinity tester provides a simple, accurate and cost-effective way to determine the salt concentration in saltwater aquariums. Features at a Glance Seawater Salinity by Conductivity All salinity measurements displayed on the large multi-level LCD are calculated from a conductivity measurement based upon known tables including the International Oceanographic Tables for ppt readings. Choice of Measurement Units Displays results in parts per thousand (ppt), Practical Salinity Units (PSU), or specific gravity (S.G.). Automatic Temperature Compensation Conductivity measurements are very sensitive to temperature variations. HI98319 has an exposed temperature sensor for a rapid temperature compensated salinity measurement. Graphite Sensors Reduces polarization effects common testers that use with stainless steel and does not oxidize resulting in a reliable and accurate readings.   Automatic Calibration A 35.00 ppt solution is used for calibration and automatically recognized when in calibration mode. Automatic Shut-off Selectable from 8 minutes, 60 minutes, or disabled. Long Battery Life Approximately 100 hours of continuous use. Plastic Carrying Case The 98319 is supplied complete with meter and 35 ppt calibration sachets in a durable plastic storage case.   Salinity Range 0.0 to 70.0 ppt (g/L) Salinity Resolution (ppt) 0.1 ppt (g/L) Salinity Accuracy (ppt) 1 ppt for 0.0 to 40.0 ppt; 2 ppt for readings over 40.0 ppt Salinity Calibration (ppt) all ranges calibrated with 35.00 ppt salinity standard Salinity (PSU) Range 0.0 to 70.0 PSU Salinity (PSU) Resolution 0.1 PSU Salinity (PSU) Accuracy 1 PSU for 0.0 to 40.0 PSU ; 2 PSU for readings over 40.0 PSU Specific Gravity Range 1.000 to 1.041 S.G. Specific Gravity Resolution 0.001 S.G. Specific Gravity Accuracy 0.001 S.G. Temperature Compensation automatic from 5.0 to 50.0C (41.0 to 122.0F) Salinity Method ppt - International Oceanographic Tables PSU - Standard Methods for the Examination of Water and Wastewater, 2510 B, Electrical Conductivity Method S.G.- Standard Methods for the Examination of Water and Wastewater, 2510 C, Density Method Temperature Range 0.0 to 50.0C; 32.0 to 122.0F Temperature Resolution 0.1C; 0.1F Temperature Accuracy 0.5C; 1F Automatic Shut-Off user selectable 8 minutes, 60 minutes, or disabled Battery Type/Life CR2032 3V lithium ion / approximately 100 hours Environment 0 to 50C (32 to 122F); RH max 100% Dimensions 160 x 40 x 17 mm (6.3 x 1.6 x 0.7) Weight 68 g (2.4 oz.) without battery Ordering Information HI98319 is supplied with protective cap, 35.00 ppt calibration solution sachet (4), CR2032 battery (1), plastic storage case, instrument quality certificate and instructional manual. read more
Hanna Instruments (M) Sdn Bhd added new photo in Benchtop Photometers
Apr 29, 2020 at 01:15 pm —
HI839800 COD Test Tube Heater

HI839800 COD Test Tube Heater

RM 4,166.00

The HI839800 COD Test Tube Heater is an easy to use thermoreactor constructed of durable materials. The aluminum block incorporates a 25 vial capacity and a well for a reference temperature probe. Its well-marked user interface provides intuitive operation, equipped with two arrows to set the built-in timer and a temperature button with two predefined temperature settings: 150ºC and 105ºC. Additional features include status indicator lights, a thermal fuse to prevent overheating, and continuous LCD display. Low and high temperature alerts Built-in countdown timer Status indicator lights COD Test Tube Heater features two predefined temperature profiles: 150ºC and 105ºC. Digestions for chemical oxygen (COD) and total phosphorus are conducted at 150ºC, while total nitrogen digestions are conducted at 105ºC. The test tube heater automatically heats up to the set temperature, holding it until the countdown timer has finished. Once the timer has ended, a beep will sound and the heating element will turn off. The outer casing of the HI839800 remains cool to the touch, even during a timed digestion. An optional lab safety shield and test tube cooling rack provide a complete setup for sample digestions. Features at-a-glance Predefined Temperature Settings - The test tube heater features two predefined temperature profiles at 150ºC (221ºF) and 105ºC (301ºF) that can be selected at the press of a button. Temperature Alerts - The HI839800 alerts users in the event that the temperature of the heating block is either above or below the set temperature. A timer icon reminds users to wait until the heating block has cooled or warmed up before inserting their samples. Built-in Timer - A built-in countdown timer of up to 180 minutes allows users to easily set the required digestion time by simply pressing the up and down arrows. Once a time has been set and the heating element is stable, a press of the START button begins the digestion procedure. Status Indicator Lights - Three LED lights are featured on the HI839800. A green LED indicates the heater has been turned on; a yellow LED indicates when the heater is actively heating up to a set temperature; a red LED indicates when the heater goes above 50ºC, reminding the user that the aluminum element is hot. Overheating Prevention - The HI839800 contains a thermal fuse that prevents overheating. Should overheating occur, the heater automatically shuts down and all LED indicator lights turn off. Reference Temperature Well - In addition to the 25 vial capacity of the aluminum heating block, a small well is available for a temperature probe for users that wish to verify their heating block. Two Operating Modes - The HI839800 features two operating modes: idle and heating. Idle mode is the default mode in which the heater measures and displays the current temperature, target temperature, set reaction time, and an idle tag. Heating mode is activated when users press the START button; it starts when actively heating and continues during the countdown timer. Continuous LCD Display - The block temperature is continuously displayed on the easy to read LCD display, even when there is no active temperature program running. All relevant information in addition to temperature are easily visible during idle and heating mode. Error Messages - Messages on display alerting to problems including high or low temperature, hot surface, or heating system malfunction.   COD Test Tube Heater Qty: read more
Hanna Instruments (M) Sdn Bhd added new photo in Titrators - Autotitrator
Aug 16, 2019 at 12:09 pm —
HI931  Automatic Potentiometric Titrator

HI931 Automatic Potentiometric Titrator

RM 22,800.00

The HI931 Automatic Titrator is the answer to your dedicated titration needs. Fully customizable, the HI931 delivers accurate results and intuitive user experience, all in a compact package. Titrate for a variety of measurements at the push of a button including acids, bases, redox, and selective ions. With no additional programming upgrades to purchase, you can start measuring right away. Small footprint so you can fully optimize your benchtop and increase productivity. Unmatched 40,000-step dosing pump for small volumes of titrant to help you achieve a very precise endpoint for greater consistency. Perfect for dedicated titration needs.       Details Superior design for superior results. The Cycoloy® body is durable, heat-resistant, and resists staining. Menu buttons are part of the display making it fully sealed and easy to clean. A high contrast LCD display makes every character on the display stand out and the wide viewing angle allows measurements to be seen from any angle. The backlight is adjustable for perfect viewing and a backlight saver option protects the display during periods of inactivity.   Maximize your workspace. This new generation of titrator features a 50% smaller footprint than the HI901 Automatic Titratorfor maximum use of your lab space. Use it in any sized space while providing accurate and consistent results.   Simple User Experience Virtual keys present on the display allow for simple and quick navigation between screens and menus without getting lost in a nest of information. If you need additional information about a screen, simply press the dedicated button for help.     Multiple Titration Types Paired with the right electrode, this potentiometric titrator can perform any number of standard titrations including pH and mV tests with fixed endpoints or single equivalence points.   Track Your Progress A real-time titration curve can be displayed during each titration; this feature is useful when new methods are tested or when a procedure requires optimization.   Enhanced Security Options Administrative users can set a PIN code on the device protecting against unauthorized access. Titration method options and results are tamper-proof while a non-administrator operates the titrator, ensuring records remain safe, secure, and traceable.   Exchangeable Burette System With Hannas Clip-Lock™ burette feature, it only takes a few seconds to exchange titrants and reagents preventing cross-contamination and saving time.   Precision Dosing Pump Our unmatched 40,000-step piston driven pump is capable of dosing extremely small and highly accurate volumes of titrant or reagent.   Chemically Resistant Tubing Aspiration and dispensing tubes are constructed of durable, chemically resistant PTFE and feature a light-blocking polyurethane outer sleeve to protect light sensitive reagents. Flexible Electrode Holder This electrode holder can hold up to 3 electrodes, 4 tubes, and 1 temperature probe at any given time. The holder is angled and the stirrer is removable for access to smaller volume titrations without hassle. Use electrodes with different diameters when needed simply by changing the electrode guide. No need to move electrodes around, get the best tube alignment for your titration with a rotating holder.   Adjustable Arm For a more compact design, the electrode holder is built directly into the titrator body. The press-to-release button makes for simple height control. Need to save more space? Just reverse the holder to accommodate larger beakers.   Smarter Stirring The removable overhead stirrer has built-in speed control for more consistent stirring. Take advantage of the versatility. HI931 functions as a titrator, pH meter, mV/ORP meter, and ISE meter. Valuable laboratory bench space is saved, and multiple tests can be performed on one sample.   Stay connected. Connect the devices that help you most, whether it be an analytical balance for automatic weight sample entry or a printer for your reports.   View and print reports easily. You can print reports directly from the titrator with a connected printer.     Customizable Analysis Reports Each analysis report is fully customizable so users can ensure they are storing and filing the best data required for their application. New multiselect feature makes batch processing simple.   Flexible GLP Management All necessary GLP (Good Laboratory Practice) information is recorded with each sample including sample identification, company and operator name, date, time, electrode ID codes, and calibration information.   Effortless Data Transfer A conveniently located USB port or direct connection to a PC allows for the transfer of titration methods, titration reports, and software upgrades. Easily convert titration methods from our software to an LIMS friendly format.   Need more? Upgrade to the HI932 Advanced Automatic Potentiometric Titrator for more complex analyses. HI932 - Advanced Automatic Potentiometric Titrator pH Specifications pH Range -2.000 to 20.000 pH pH Resolution 0.1; 0.01; 0.001 pH pH Accuracy (@25ºC/77ºF) 0.001 pH pH Calibration up to five-point calibration, eight standard buffers and five custom buffers mV Specifications mV Range -2000.0 to 2000.0 mV mV Resolution 0.1 mV mV Accuracy (@25ºC/77ºF) 0.1 mV mV Calibration single-point offset ISE Specifications ISE Range 1•10⁻⁶ to 9.99•10¹⁰ ISE Resolution 1; 0.1; 0.01 ISE Accuracy 0.001 pH ISE Calibration up to five-point calibration, seven standard solutions and five user-defined standards Temperature Specifications Temperature Range -5.0 to 105.0C; 23.0 to 221.0F; 268.2 to 378.2K Temperature Resolution 0.1C; 0.1F; 0.1K Temperature Accuracy (@25ºC/77ºF) 0.1C; 0.2F; 0.1K, excluding probe error Additional Specifications Programmable Stirrer overhead propeller type, 200 to 2500 rpm, resolution 100 rpm Display 5.7 (320 x 240 pixel) backlit color LCD Burette Sizes 5, 10, 25, and 50 mL Burette Resolution 1/40000 Display Resolution 0.001 mL Dosing Accuracy 0.1% of full burette volume Methods up to 100 methods (standard and user-defined) Logging Data up to 100 titration and pH/mV/ISE reports Burette Auto-Detection burette size is automatically recognized when inserted into the unit Flow Rate user-selectable from 0.1 mL/min to 2 x burette volume/min Endpoint Determination single equivalence point (1st or 2nd derivative) or fixed pH/mV value Potentiometric Titrations acid/base (pH or mV-mode), redox, precipitation, complexometric, non-aqueous, ion-selective, argentometric Measurement Units user-specified expression of concentration units to suit specific calculation requirements Real-Time & Stored Graphs mV-volume or pH-volume titration curve, 1st derivative curve or 2nd derivative curve; pH mode, mV mode or ISE mode: pH/mV/concentration versus time USB Host (Side) flash drive compatibility for transfer of methods and reports GLP Conformity instrumentation data storage and printing capabilities Languages English, Portuguese, Spanish Operating Environment 10 to 40C (50 to 104F), up to 95% RH Storage Environment -20 to 70C (-4 to 158F), up to 95% RH Power Supply 100-240 VAC; '-01' models, US plug (type A); '-02' models, European plug (type C) Dimensions 315 x 205 x 375 mm (12.4 x 8.1 x 14.8 ') Weight approx. 4.3 kg (9.5 lbs.) with 1 pump, stirrer and sensors Ordering Information Each HI931 potentiometric titrator is supplied with: Titrator, Pump Assembly, Burette Assembly, Electrodes Holder and Stirrer, Burette Blank Support, Pump and Burette Locking Screws with Plastic Head, Temperature Sensor, Shorting Cap, Power Adapter, USB Cable, Instruction Manual, USB Memory Stick, HI900 PC Application (Installation Kit on USB Stick), and Quality Certificate. read more
Hanna Instruments (M) Sdn Bhd added new photo in Titrators - Advanced Titrator
Aug 16, 2019 at 12:06 pm —
HI932  Advanced Automatic Potentiometric Titrator

HI932 Advanced Automatic Potentiometric Titrator

RM 40,400.00

The HI932 Advanced Automatic Titrator is the answer to your advanced titration needs. Fully customizable to meet your testing needs, the HI932 delivers accurate results and intuitive user experience, all in a compact package. Titrate for a variety of published methods at the push of a button, as well as perform direct measurements and back titrations for complex samples. For those that require greater automation, pair your HI932 with the HI922 Autosampler for the most accurate results with the least amount of effort. Small footprint so you can fully optimize your benchtop and increase productivity. Reduce downtime and increase efficiency when you perform multiple analyses linked in sequence. Works seamlessly with the HI922 Autosampler for automation of up to 18 samples.       Details Superior design for superior results. The Cycoloy® body is durable, heat-resistant, and resists staining. Menu buttons are part of the display making it fully sealed and easy to clean. A high contrast LCD display makes every character on the display stand out and the wide viewing angle allows measurements to be seen from any angle. The backlight is adjustable for perfect viewing and a backlight saver option protects the display during periods of inactivity.   Maximize your workspace. This new generation of titrator features a 50% smaller footprint than the HI902 Automatic Titratorfor maximum use of your lab space. Use it in any sized space while providing accurate and consistent results.   Simple User Experience Virtual keys present on the display allow for simple and quick navigation between screens and menus without getting lost in a nest of information. If you need additional information about a screen, simply press the dedicated button for help. Multiple Titration Types Paired with the right electrode from our sensor line, this potentiometric titrator can perform any number of standard titrations, back titrations, as well as perform direct pH, ORP, and ion selective readings.   Streamline Your Testing Reduce downtime and increase efficiency when you perform multiple analyses linked in sequence. A linked method function allows for two analyses to be run on the same sample including direct measurements, fixed endpoint titrations, multiple (up to 5) equivalence point titrations, and back titrations. Track your progress in real-time with onscreen titration curves.   Enhanced Security Options Administrative users can set a PIN code on the device protecting against unauthorized access. Titration method options and results are tamper-proof while a non-administrator operates the titrator, ensuring records remain safe, secure, and traceable.   Exchangeable Burette System With Hannas Clip-Lock™ burette feature, it only takes a few seconds to exchange titrants and reagents preventing cross-contamination and saving time.   Precision Dosing Pump Our unmatched 40,000-step piston driven pump is capable of dosing extremely small and highly accurate volumes of titrant or reagent.   Chemically Resistant Tubing Aspiration and dispensing tubes are constructed of durable, chemically resistant PTFE and feature a light-blocking polyurethane outer sleeve to protect light sensitive reagents. Flexible Electrode Holder This electrode holder can hold up to 3 electrodes, 4 tubes, and 1 temperature probe at any given time. The holder is angled and the stirrer is removable for access to smaller volume titrations without hassle. Use electrodes with different diameters when needed simply by changing the electrode guide. No need to move electrodes around, get the best tube alignment for your titration with a rotating holder.   Adjustable Arm For a more compact design, the electrode holder is built directly into the titrator body. The press-to-release button makes for simple height control. Need to save more space? Just reverse the holder to accommodate larger beakers.   Smarter Stirring The removable overhead stirrer has built-in speed control for more consistent stirring. Automatic Reagent Addition A peristaltic pump may be programmed to volumetrically dispense reagent prior to titration or direct measurement or aspirate post-analysis. This helps achieve consistent and accurate results and prevents operator errors such as incorrect volumes or forgetting reagent addition. Designed for dynamic environments. Don't worry about small spills in the laboratory with built-in spill handling. An external gutter system protects important connections and interior trays safeguard internal electronics.     Take advantage of the versatility. HI932 functions as a titrator, pH meter, mV/ORP meter, and ISE meter. Valuable laboratory bench space is saved, and multiple tests can be performed on one sample.   Stay connected. Connect the devices that help you most, whether it be an analytical balance for automatic weight sample entry or a printer for your reports.   View and print reports easily. You can print reports directly from the titrator with a connected printer.   Customizable Analysis Reports Each analysis report is fully customizable so users can ensure they are storing and filing the best data required for their application. New multiselect feature makes batch processing simple.   Flexible GLP Management All necessary GLP (Good Laboratory Practice) information is recorded with each sample including sample identification, company and operator name, date, time, electrode ID codes, and calibration information.   Effortless Data Transfer A conveniently located USB port or direct connection to a PC allows for the transfer of titration methods, titration reports, and software upgrades. Easily convert titration methods from our software to an LIMS friendly format.   pH Specifications pH Range -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH pH Resolution 0.1; 0.01; 0.001 pH pH Accuracy (@25ºC/77ºF) 0.001 pH pH Calibration up to five-point calibration, eight standard buffers and five custom buffers mV Specifications mV Range -2000.0 to 2000.0 mV mV Resolution 0.1 mV mV Accuracy (@25ºC/77ºF) 0.1 mV mV Calibration single-point offset ISE Specifications ISE Range 1•10⁻⁶ to 9.99•10¹⁰ ISE Resolution 1; 0.1; 0.01 ISE Accuracy 0.5% monovalent; 1% divalent ISE Calibration up to five-point calibration, seven standard solutions and five user-defined standards Temperature Specifications Temperature Range -5.0 to 105.0C; 23.0 to 221.0F; 268.2 to 378.2K Temperature Resolution 0.1C; 0.1F; 0.1K Temperature Accuracy (@25ºC/77ºF) 0.1C; 0.2F; 0.1K, excluding probe error Temperature Compensation manual (MTC) or automatic (ATC) Additional Specifications Programmable Stirrer propeller type, 100 to 2500 rpm, resolution 100 rpm Display 5.7 (320 x 240 pixel) backlit color LCD Burette Sizes 5, 10, 25, and 50 mL Burette Resolution 1/40000 Display Resolution 0.001 mL Dosing Accuracy 0.1% of full burette volume Methods up to 100 methods (standard and user-defined) Burette Auto-Detection burette size is automatically recognized when inserted into the unit Flow Rate user-selectable from 0.1 mL/min to 2 x burette volume/min Endpoint Determination equivalence point (1st or 2nd derivative) or fixed pH/mV value Potentiometric Titrations acid/base (pH or mV-mode), redox, precipitation, complexometric, non-aqueous, ion-selective, argentometric Measurement Units user-specified expression of concentration units to suit specific calculation requirements Real-Time & Stored Graphs mV-volume or pH-volume titration curve, 1st derivative curve or 2nd derivative curve; pH mode, mV mode or ISE mode: pH/mV/concentration versus time USB Host (Side) flash drive compatibility for transfer of methods and reports GLP Conformity instrumentation data storage and printing capabilities Languages English, Portuguese, Spanish Operating Environment 10 to 40C (50 to 104F), up to 95% RH Storage Environment -20 to 70C (-4 to 158F), up to 95% RH Power Supply 100-240 VAC; '-01' models, US plug (type A); '-02' models, European plug (type C) Dimensions 315 x 205 x 375 mm (12.4 x 8.1 x 14.8 ') Weight approx. 4.3 kg (9.5 lbs.) with 1 pump, stirrer and sensors Ordering Information Each HI932 potentiometric titrator is supplied with: Titrator, Pump Assembly, Burette Assembly, Electrodes Holder and Stirrer, Burette Blank Support, Pump and Burette Locking Screws with Plastic Head, Temperature Sensor, Shorting Cap, Power Adapter, USB Cable, Instruction Manual, USB Memory Stick, HI900 PC Application (Installation Kit on USB Stick), and Quality Certificate.   read more
Hanna Instruments (M) Sdn Bhd added a news
Apr 23, 2019 at 10:59 am —
Hanna Instruments (M) Sdn Bhd updated website's banner
Oct 11, 2018 at 03:01 pm —
Hanna Instruments (M) Sdn Bhd updated website's banner
Oct 11, 2018 at 02:56 pm —
Hanna Instruments (M) Sdn Bhd updated website's banner
Oct 11, 2018 at 02:52 pm —
next page

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version