HI98143 pH and EC Transmitter with Galvanic Isolated Output

Previous 13 / 15 Next

HI98143 pH and EC Transmitter with Galvanic Isolated Output Controllers, Analyzers & Transmitters Process Control
RM 2,776.00
600 g

In Stock


Download Files

manhi_98143_01_04_20_22.pdf (359.18 KB)
The HI98143 series is specially designed for long distance measurements of pH and Electrical Conductivity in industrial applications. It can be either panel or wall mounted.

  • Four models are available.
  • Automatic temperature compensation Connectivity.
  • PC compatible.

Direct Connection

  • Direct connection of the probes to the transmitter assure a positive electrical connection with no signal loss. This transmitter is ideal for remote process control applications.

Connectivity

  • The transmitter can be connected to any pH or conductivity controller, recorder, PC or any data monitoring device that accepts 0 to 1 V, 0 to 4 V or 4 to 20 mA input.

Output Signals

  • Four models are available, transmitting a 0-1 V, 0-4 V or 4-20 mA signal. The output signals are proportional to the input signals but independent of changes in load or cable capacitance.

Friendly Design

  • Probes connectors, power supply, contacts and calibration trimmers are easy to reach directly on the front panel.

Automatic Temperature Compensation

  • Compensation for the effects of temperature for EC measurements are performed by the transmitters’ Automatic Temperature Compenstion circuitry.

Versatile Use

  • For in-line applications the recommended pH electrode is the HI1001 while the conductivity probe is the HI3001. HI1001 is a combined double junction pH electrode with BNC and 3m cable; HI3001 is a 4-ring conductivity probe with platinum sensors and an int

pH

pH Range 0 to 14 pH
pH Accuracy ±0.5% f.s. pH
pH Calibration manual, 2 point, through trimmers: pH: offset and slope trimmers

EC/TDS

EC Range 0 to 10 mS/cm
EC Accuracy ±2% f.s. EC
EC Calibration manual, 2 point, through trimmers: EC: 0 and 5 mS/cm trimmers
EC/TDS Temperature Compensation automatic, 0 to 60°C (32 to 132°F) with β=2%/°C

General Meter

pH Electrode HI1001 pH electrode (suggested, not included), HI1283 matching pin (not included)
EC/TDS Probe HI3001 (not included) with cell constant 2.1

Process Control Meter

Power Supply 12-24 VDC
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
IP Rating IP54
Dimensions 160 x 105 x 31 mm (6.3 x 4.1 x 1.2’’)
Weight 280 g (9.9 oz.
Ordering Information All HI98143 models are supplied with instructions.

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Recent Updates
Subscribe Newsletter