BL983327-1 Conductivity Mini Controller (0.00-10.00 mS/cm)

Previous 8 / 16 Next

BL983327-1 Conductivity Mini Controller (0.00-10.00 mS/cm) Mini Controllers Process Control BL983327-1 Conductivity Mini Controller (0.00-10.00 mS/cm) Mini Controllers Process Control BL983327-1 Conductivity Mini Controller (0.00-10.00 mS/cm) Mini Controllers Process Control
RM 1,111.00
SKU: BL983327-1
300 g
8 cm (L) x 5 cm (W) x 10 cm (H)
In Stock


Download Files

manbl983313_09_22_web.pdf (708.47 KB)

The BL983327 is a compact, panel mounted, process controller for measuring conductivity of a process stream. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid valve to open and drain a tank (i.e. boiler bleed and feed) or add freshwater until the desired set point is reached.

The BL983317 is a closely related product that has the same measurement range but has a relay that is activated when the reading is below the set point.

Multicolor LED Indicator

LED changes color based on status.
 

Fire Retardant Casing

For additional safety the controllers outer case is made of fire resistant plastic.

Splash Resistant Cover

A clear plastic cover protects the face panel from dirt and liquids.

 

BL983327

Adjustable Dry Contact Dosing Relay

The BL983327 features a dosing relay that is activated when the reading is above a user programmable set point.

Programmable Overdose Protection

For enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.

Relay Control Override

With the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.

Multicolor LED Indicator

Multicolor LED indicator allows an operator to quickly check the status of the controller.

  • Green = Meter in measurement mode and reading is below the set point.
  • Orange/Yellow = Reading is above the set point and the relay is active.
  • Blinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.
BL983327

Fuse Protected Dosing Contacts

The relay dosing contact is rated for up to a 2A load and is fuse protected.

Labeled Termination Connections

Quick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.

HI7632

1/2'' NPT Male Threaded Amperometric Probe for Mounting In-line*

The BL983327 mini controller uses the HI7632 conductivity probe that is available with different cable lengths.

*HI7632 is not included and must be ordered separately

 

BL931700

Front View

Installation cut-out dimensions are provided as well as outside panel dimensions.

BL931700

Side View

Adjustable location brackets allow the controller to slide easily and securely into place.
 

 

SKU BL983327-web
Product Name Conductivity Mini Controller (0.00-10.00 mS/cm) - BL983327
Quote Required Yes
EC Range 0.00 to 10.00 mS/cm
EC Resolution 0.01 mS/cm
EC Accuracy ±2% full scale
EC Calibration manual, with CAL trimmer
EC/TDS Temperature Compensation automatic from 5 to 50°C (41 to 122°F) with β =2%/oC
EC/TDS Dosing Relay maximum 2A (fuse protected), 250 Vac, 30 VDC
EC/TDS Dosing Set Point adjustable from 0 to 10 mS/cm
Dosing Control contact closed when measure > setpoint
Over Dosing Control adjustable, typically from 5 to approximately 30 minutes
Power Supply models “-0”
Dimensions 83 x 53 x 99 mm (3.3 x 2.1 x 3.9’’)
Weight models “-0”
Ordering Information BL983327-0 (12 VDC) and BL983327-1 (115/230VAC) are supplied with mounting brackets, transparent cover and instruction manual.

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Recent Updates
Subscribe Newsletter