Hanna Instruments (M) Sdn Bhd
11A, Jalan PJS 11/20,
Bandar Sunway,
46150 Petaling Jaya,
Selangor, Malaysia.
+603-5638 9940

Penang Branch Office
Hanna Instruments (M) Sdn Bhd
N0. 303-2-27, Krystal Point,
Jalan Sultan Azlan Shah,
11900 Sungai Nibong,
Penang, Malaysia.
+604-638 4558
+604-645 4558
penang@hannamalaysia.com

Sabah Branch Office
Hanna Instruments (M) Sdn Bhd

No. 4-1, 1st Floor,
Plaza Kingfisher,
Jalan Plaza Kingfisher 5,
Inanam, 88450 Kota Kinabalu,
Sabah, East Malaysia.
088-382 941
088-382 942
sabah@hannamalaysia.com


HI10480 Digital Glass Body pH Electrode with Clogging Prevention System (CPS™)

Previous 69 / 82 Next

HI10480 Digital Glass Body pH Electrode with Clogging Prevention System (CPS™) pH Electrodes & Probes HI10480 Digital Glass Body pH Electrode with Clogging Prevention System (CPS™) pH Electrodes & Probes
RM 1,349.00
500 g
In Stock


The HI10480 is a digital pH electrode with built-in temperature sensor. This application specific electrode is designed for measuring pH in wine and must. Measuring the pH of wine is a critical step to ensure the quality of a final product.

 

This electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a double junction reference, Clogging Prevention System (CPS) technology, glass body, and spherical tip. This probe is designed for use with compatible Hanna meters with a 3.5 mm input.

  • Spherical Glass Tip
  • Clogging Prevention System
  • 3.5 mm Connector

Details

digital electrode

Built-In Microchip

The built-in microchip stores sensor type, serial number and calibration information including date, time, offset, slope, probe condition and buffers used. This information is automatically retrieved by edge® once the electrode is plugged in. The ability to transfer information allows for hot swapping of probes without having to recalibrate. All pH measurements are performed within the electrode and transferred digitally to the meter. This overcomes any noise issues associated with the traditional high impedance analog measuring system. Electrical noise can be generated from a built in temperature sensor and while working in a humid environment.

 

spherical tip

Spherical Glass Tip

The spherical shaped tip design allows for a wide area of contact with the measured sample. This permits a faster electrode response with a higher degree of stability.  The HI10480 utilizes a low temperature (LT) glass formulation that has a resistance of around 50 megaohms at 25°C. As the temperature of the glass decreases in the sample, the resistance of the LT glass will approach that of GP glass. If using GP glass, the resistance would increase above the optimum range, resulting in increased impedance and ultimately affecting the measurement. The HI10480 is suitable to use with samples that measure from 0 to 80°C.

 

CPS clog prevention

CPS Sleeve Junction


CPS™ (Clogging Prevention System) is an innovation in electrode technology. Conventional pH electrodes use ceramic junctions that clog quickly when used in wine. When the junction is clogged, the electrode does not function. CPS™ technology utilizes the porousness of ground glass coupled with a PTFE sleeve to prevent clogging of the junction. The ground glass allows proper flow of the liquid, while the PTFE sleeve repels dirt. As a result, pH electrodes with CPS™ stay fresh up to 20 times longer than conventional electrodes.

 

open junction

Double Junction Reference

A double junction electrode has an internal compartment surrounding the reference wire. Silver ions are present in the electrolyte of the internal compartment, which houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver free. The double junction design means that virtually no silver from the electrode enters the sample. This design allows measurement in applications where silver ions in the sample are undesirable or silver precipitates on the junction are likely to form.

 

glass body

Glass Electrode Body

The glass electrode body is suitable for a wide range of applications due to its chemical resistance. The glass electrode is compatible with many non-aqueous solvents and other aggressive chemicals. Glass is also resistant to many forms of radiation, such as ultraviolet radiation.

 

 

 

 

Specifications

Body Material glass
Reference double
Junction / Flow Rate open, CPS technology
Clogging Prevention System yes
Electrolyte 3.5M KCl
Range pH: 0 to 12
Max Pressure 0.1 bar
Tip Shape spheric
Diameter 12 mm
Body Length / Overall Length 120 mm / 175.5 mm
Recommended Operating Temperature 0 to 80°C (32 to 176°F)
Temperature Sensor yes
Matching Pin no
Amplifier no
Digital yes
Compatible Meters edge multiparameter, edge dedicated
Cable coaxial; 1 m (3.3’)
Connection 3.5 mm connector
Applications application specific purpose, samples with suspended solids, wine

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Recent Updates
Subscribe Newsletter